GW Instek LCR-8205 - DC, 10Hz ~ 5MHz High-Frequency LCR Meter
GW Instek launches a new series of high-frequency LCR meter ~ LCR-8200, which has four models and the maximum test frequency is up to 30MHz. The entire series adopts 7-inch color display and features a high measurement accuracy (0.08%). The measurement results can be presented numerically or graphically according to the selected measurement mode, allowing users to optimally interpret the characteristics of the DUT. At the same time, a full range of standard interfaces such as USB device / RS-232C / Handler and GPIB allow users to control the instrument by the most familiar interface without worrying about additional hardware investment costs. Furthermore, the series also provides USB storage function when operating in the graphics mode. The measured characteristic curves and values of the DUT are saved for subsequent analysis. The wide variety of features of the LCR-8200 can help users easily respond to the test requirements of passive components in R&D, engineering, and production.
- Wide Test Frequency 10Hz ~ 30MHz/20MHz/10MHz/5MHz
- 7” LCD color Display
- 0.08% Basic Accuracy
- Displaying Four Measurement results simultaneously from 17 selectable measurement parameters freely
- 15 steps List Measurement
- Two Curves Sweep Mode
- Internal DC Bias Voltage ±12V
- USB Storage available
- ALC function available
- Standard Interfaces : RS-232C, USB host/device, LAN, GPIB and Handler
- Universal power input
General
Test Frequency | DC, 10Hz ~ 20MHz; 6 Digits, ±0.0007% |
Output Impedance | 25Ω / 100Ω Selectable |
Basic Accuracy | ±0.08% |
Test Speed | Max: 25ms(>10kHz), Fast: 50ms(>20Hz), Medium: 100ms Slow: 300ms, Slow2: 600ms |
Dimensions & Weight | 346 (W) X 145 (H) X 335 (D) mm; Approx. 3.3kg |
Measurement Parameters | Maximum four parameters can be measured and displayed at the same time Impedance (Z), Inductance (Ls / Lp), Capacitance (Cs / Cp), AC Resistance (Rs / Rp), Quality Factor (Q), Dissipation Factor (D), Admittance (Y), Conductance (G), Reactance (X), Phase Angle (θd / θr), Susceptance (B), DC Resistance (Rdc) |
Interface | USB/GPIB/LAN/RS-232/Handler/USB Host/TRIGGER Input |
Power Source | AC 100V~240V, 50/60Hz; Consumption: 65VA (max.) |
Display | 7" LCD color display (800x480) |
Test Signal Level
AC Voltage | 10mV ~ 2Vrms (FREQ. ≦ 1MHz), 10mV ~ 1Vrms (FREQ. > 1MHz or FREQ. ≦ 1MHz and RO=25Ω) |
AC Current | 100μA ~ 20mArms (RO=100Ω), 200μA ~ 40mArms (RO=25Ω) |
DCR Voltage | 1Vdc (40mA max.) |
List measurement
Listed Steps | 15 |
Listed Parameters | Freq/Vac/Iac/DC Bias/Comp/BIN |
Trigger | auto, Repeat, Single |
Sweep Measurement
Swept Graphical | Two of measurement parameters |
Swept Parameters | Freq/Vac/Iac, Keep Trace |
Other Functions
Auto Level Control (ALC) | standard |
DC Bias | 0 ~ ±12V |
Handler | PASS, FAIL and OK, NG or BIN 1-9 |
Other Features
Correction | Open/Short/HF Load/Load |
V/I Monitor | Vac, Iac, Vdc, Idc |
Comparator | Value, Δ, Δ% |
Buzzer | Off, Pass, Fail |
Average | 1 to 64 |
Do you have a DC, 10Hz ~ 5MHz High-Frequency LCR Meter that needs to be calibrated?
We offer standard traceable calibration and ISO 17025 accredited calibration services.
Get your DC, 10Hz ~ 5MHz High-Frequency LCR Meter calibrated today! Click Here!