GW Instek GDS-1202B - 200MHz, 2 channels, Digital Storage Oscilloscope
Realizing Professional Functionalities with an Entry-Level Pricing
The GDS-1000B Series features four bandwidth selections - 200MHz, 100 MHz, 70 MHz, 50MHz and equips with analog signal input terminals by four or two channels. The maximum sampling rate for every single channel is 1GSa/s, and the memory depth is 10Mpts per channel independently. The GDS-1000B Series has a waveform update rate of 50,000wfms/s, which helps users to precisely observe the detailed waveform variation. Additionally, 7” WVGA color LCD and the 256 color gradient display function together allow waveforms to be observed with the senses of transparency and gradation.
Concerning the horizontal time scale adjustment knob and trigger level adjustment knob, GW Instek provides a very thoughtful design -the zero key function, which allows engineers to work more effectively. For mathematical analysis mode, 1Mpts FFT signal display makes the dull frequency domain signal analysis more delicate.
Moreover, the innovative exterior design and compact design also bring much convenience to users. Another diversified and charming multi-functional operation demonstrates the concept of complete technology integration.
- 50/70/100MHz bandwidth selections, 2ch or 4ch input
- 1GSa/s maximum sampling rate
- 10M maximum memory depth for each channel
- 7” 800 x 480 WVGA LCD display
- 256 color gradient display function to strengthen waveform performance
- 1Mpts FFT frequency domain signal display
- Zero Key function for horizontal time, vertical voltage and triggering
- Compact and innovative exterior design
General Specifications
Bandwidth (-3dB) | DC coupling: DC ~ 200MHz |
Channels | 2 |
Rise | 1.75ns |
Bandwidth Limit | 20MHz |
Vertical
Resolution | 8 bit : 1mV~10V/div |
Input Coupling | AC, DC, GND |
Input Impedance | 1M&ohms;/ 16pF approx |
DC Gain Accuracy | ±3% |
Polarity | Normal & Invert |
Maximum Input Voltage | 300Vpk, CATI (300Vpk CATII with GTP-070A-4, GTP-100A-4 10:1 probe |
Offset Position Range | 1mV/div ~ 20mV/div: ±0.5V 50mV/div ~ 200mV/div: ±5V 500mV/div ~ 2V/div: ±25V 5V/div ~ 10V/div: ±250V |
Waveform Signal Process | +, -, ×, ÷, FFT, FFTrms, User defined expression |
FFT: Spectral magnitude. Set FFT Vertical Scale to Linear RMS or dBV RMS, and FFT Window to Rectangular, Hamming, Hanning, or Blackman-Harris |
Trigger
Source | CH1, CH2, CH3*, CH4*, Line, EXT** *4 channel models only. **2 channel models only. |
Trigger Mode | Auto (supports Roll Mode for 100 ms/div and slower), Normal, Single |
Trigger Type | Edge, Pulse Width, Video, Pulse Runt, Rise & Fall, Timeout, Alternate, Event-Delay (1~65535 events), Time-Delay (Duration: 4nS~10S), Bus |
Holdoff range | 4ns to 10s |
Coupling | AC, DC, LF rej., Hf rej., Noise rej. |
Sensitivity | 1 div |
External Trigger
Range | ±15V |
Sensitivity | DC ~ 100MHz Approx. 100mV |
Input Impedance | 1M&ohms;±3% ~ 16pF |
Horizontal
Timebase Range | 1ns/div ~ 100s/div (1-2-5 increments) ROLL: 100ms/div ~ 100s/div |
Pre-trigger | 10 div maximum |
Post-trigger | 2,000,000 div maximum |
Timebase Accuracy | ±50 ppm over any ≥ 1ms time interval |
Real Time Sample Rate | 1GSa/s, max. |
Record Length | Maximum 10Mpts |
Acquisition Mode | Normal, Average, Peak Detect, Single |
Peak Detection | 2ns (typical) |
Average | Selectable from 2 to 256 |
X-Y Mode
X-Axis Input | Channel 1; Channel 3* *4 channel models only. |
Y-Axis Input | Channel 2; Channel 4* *4 channel models only. |
Phase Shift | ±3° at 100kHz |
Cursors and Measurement
Cursors | Amplitude, Time, Gating available; Unit: seconds(s), Hz(1/s), Phase(degree), Ration(%) |
Automatic Measurement | 36 sets: Pk-Pk, Max, Min, Amplitude, High, Low, Mean, Cycle Mean, RMS, Cycle RMS, Area, Cycle Area, ROVShoot, FOVShoot, RPREShoot, FPREShoot, Frequency, Period, RiseTime, FallTime, +Width, -Width, Duty Cycle, +Pulses, -Pulses, +Edges, -Edges, FRR, FRF, FFR, FFF, LRR, LRF, LFR, LFF, Phase |
Cursors measurement | Voltage difference between cursors ( ΔV) Time difference between cursors ( ΔT) |
Auto counter | 6 digits, range from 2Hz minimum to the rated bandwidth |
Control Panel Function
Autoset | Single-button, automatic setup of all channels for vertical, horizontal and trigger systems, with undo Autoset |
Save Setup | 20set |
Save Waveform | 24set |
Display
TFT LCD Type | 7" TFT WVGA color display |
Display Resolution | 800 horizontal × 480 vertical pixels (WVGA) |
Interpolation | Sin(x)/x |
Waveform Display | Dots, vectors, variable persistence (16ms~4s), infinite persistence |
Waveform Update Rate | 50,000 waveforms per second, maximum |
Display Graticule | 8 x 10 divisions |
Display Mode | YT, XT |
Interface
USB Port | USB 2.0 High-speed host port X1, USB High-speed 2.0 device port X1 |
Ethernet Port | RJ-45 connector, 10/100Mbps with HP Auto-MDIX. (Only for the GDS-1074B, GDS-1104B) |
Go-NoGo BNC | 5V Max/10mA TTL open collector output |
Kensington Style Lock | Rear-panel security slot connects to standard Kensington-style lock |
Miscellaneous
Multi-language menu | Available |
Operation Environment | Temperature: 0°C to 50°C Relative Humidity: ≤ 80% at 40°C or below; ≤ 45% at 41°C ~ 50°C |
On-line help | Available |
Dimensions | 384mm x 208mm x 127.3mm |
Weight | 2.8kg |
Do you have a 200MHz, 2 channels, Digital Storage Oscilloscope that needs to be calibrated?
We offer standard traceable calibration and ISO 17025 accredited calibration services.
Get your 200MHz, 2 channels, Digital Storage Oscilloscope calibrated today! Click Here!
There are currently no reviews for this product.
Recommended Accessories for the 200MHz, 2 channels, Digital Storage Oscilloscope
Soft Carry Case for GDS-3000
Oscilloscope Education And Training Kit
Oscilloscope Probe