Soken DAC-PBV-8 - Electronic Voltage Burden

Electronic Voltage Burden

Soken

Category : Instrument Transformer Testing Set

by quote only Add to Cart

Documents:
Brochure

Overview
Features
Information
Calibration
  • Programmable burden used for voltage error testing in accordance with IEC60044-2.
  • Testing voltage can be varied over a wide range: 2 % to 190% of the rated secondary voltage.
  • Burdens from 0 to 50VA are available standalone, and a maximum of 400VA in steps of 100VA is available with optional electronic burdens.
  • USB Interface is a standard fixture.
  • Test conditions can be easily configured: the maximum of 100 test parameters (rating, burden, power factor, and lead wire compensation) are programmable.

 

Option Electric Burden

Optional burden DAC-FBV series are available in need of further VA. The burdens are controlled by DAC-PBV-8 through serial communication.

DAC-FBV Series: 50VA, 100VA, and 200VA type. When combining all units, max 400VA is available. 

 

Connecting Diagram

 

Soken DAC-PBV-8 - Electronic Voltage Burden
  • Programmable burden used for voltage error testing in accordance with IEC60044-2.
  • Testing voltage can be varied over a wide range: 2 % to 190% of the rated secondary voltage.
  • Burdens from 0 to 50VA are available standalone, and a maximum of 400VA in steps of 100VA is available with optional electronic burdens.
  • USB Interface is a standard fixture.
  • Test conditions can be easily configured: the maximum of 100 test parameters (rating, burden, power factor, and lead wire compensation) are programmable.

 

General

Rated Secondary voltage 100, 110, 115, 120, 200, 230V and each x 1/√ 3, and 100/3, 110/3, 200/3V
Test voltage range 2% to 190% of the rated secondary voltage (Max current of 12A)
Rated burden setting0.00 to 50.0 VA
Maximum of 400VA* with optional Electric burden
*Except rated secondary voltages:200, 230, 200/√ 3 and 230/√ 3
Burden Power factor
Delay: 0.20 to 1Rated burden: 0 – 35 VA
Delay: 0.5 to 1Rated burden: 35 – 75 VA
Delay: 0.8Rated burden: 75 – 400 VA with option burden
Test Frequency50/60 Hz
Settable resolution
Rated burden setting0 – 4 VA: 0.001 VA steps
4 – 20 VA: 0.01 VA steps
20 – 75 VA: 0.1 VA steps
With optional burden75 – 99.9 VA: 0.1 VA steps
100 – 400 VA: 1 VA steps
Burden Power Factor0.01 steps
Accuracy (target value) Burden and Burden Power Factor: ±4%
Communication USB (2.0/1.1)
Other FunctionsTest condition programming, over current protection, Alarm function for measuring circuit
Rated Supply Voltage100 to 240V ±10%
DimensionsW430 x H250 x D380mm (Excluding potions)