GW Instek PSW-1080L455 - Triple-Channel Programmable Switching 80V/13.5A and 2 x 160V/7.2A 1080W Multi-Range D.C. Power Supply
Second to none, dominating mid/low power ranges
PSW-Multi series is a dual-channel or triple-channel wide range output programmable switching DC power supply. The maximum output power can reach, 1080W. There are 13 dual-channel models with a rated power of 720W, and 24 triple-channel models with a rated power of 1080W. The rated voltages of low voltage modules are 30V, 40V, 80V, 160V. The rated voltages of high voltage modules are 250V and 800V.
The special functions are as follows
- The advanced web server, a unique function of the PSW-Multi series,
can directly execute SCPI commands on the server and control the PSW-Multi power supply.
The data log has an interval of 1 second. It can edit output sequence.
- Wide-range output: Provides a wide range of voltage/current outputs under the same rated power.
One power supply has the total capability of multiple power supplies.
- Bleed Circuit: Accelerates the voltage fall time.
- Sequence: Saves the output sequence in a USB flash drive to directly control the power supply to execute the automatic test sequence.
- The CC/CV priority mode of PSW-Multi is a very useful feature for protecting the DUT.
- Conventional power supplies usually operate in CV mode when outputting. During power output, capacitive loads or current-intensive loads can cause inrush currents. Taking the I-V verification curve of an LED as an example, it would be challenging to measure it using a conventional power supply. In the initial state, a conventional power supply operates in CV mode. When the output voltage exceeds the forward voltage of the LED,
the current will instantaneously flow, surpassing the default current limit value. Even when the current becomes stable after switching to CC mode, the crossover point between CV and CC can still potentially damage the DUT. However, the PSW-Multi series is capable of operating in CC mode during power output to suppress inrush currents and prevent damage to the DUT when the voltage instantaneously conducts.
- Adjustable slew rate allows users to set the rise and fall times of voltage or current.
By controlling the slew rate settings, it becomes convenient to verify the DUT under varying voltage or current conditions. In manufacturing tests for lighting devices or large capacitors, power output often generates significant inrush currents, which can greatly reduce the lifespan of the DUT. To prevent damage caused by inrush currents, a slow voltage output significantly reduces the harm caused by inrush currents, thereby achieving device protection.
- The OVP and OCP functions provided by the PSW-Multi series can be self-defined and the default value is 110% of the rated value. When the protection setting is triggered, the output will be turned off to protect the DUT.
USB and LAN are standard communications interfaces of PSW-Multi series, while GPIB-USB and RS232-USB are optional accessories. All interfaces support LabView driver and Data Logging PC software.
- Multi-channel: maximum 720W for dual-channel models and maximum 1080W for triple-channel models; output latency between channels with the same voltage module is less than 0.1ms
- Multiple voltage combinations: low voltage combinations can be selected from 30V/40V/80V/160V; high voltage combinations can be selected from 250V/800V
- Advanced web server: executes SCPI commands; controls through the server; data log; edit sequence
- CC/CV priority mode selection is ideal for battery and LED industries
- Adjustable slew rate
- High efficiency and high power density power supply
- Standard communications interfaces: LAN, USB, external analog remote control terminal
- Optional communications interfaces: GPIB-USB adapter, RS232-USB cable
- Support LabVIEW Driver
Channel 1
Module Type |
| ||||||||||||||||||||||||||||||
Constant Voltage Mode |
| ||||||||||||||||||||||||||||||
Constant Current Mode |
| ||||||||||||||||||||||||||||||
Protection Function |
| ||||||||||||||||||||||||||||||
Analog Programming and Monitoring |
| ||||||||||||||||||||||||||||||
Front Panel |
| ||||||||||||||||||||||||||||||
Programming and Measurement (USB, LAN, GPIB) |
| ||||||||||||||||||||||||||||||
Input Characteristics |
| ||||||||||||||||||||||||||||||
Interface Capabilities |
|
Channel 2
Module Type |
| ||||||||||||||||||||||||||||||
Constant Voltage Mode |
| ||||||||||||||||||||||||||||||
Constant Current Mode |
| ||||||||||||||||||||||||||||||
Protection Function |
| ||||||||||||||||||||||||||||||
Analog Programming and Monitoring |
| ||||||||||||||||||||||||||||||
Front Panel |
| ||||||||||||||||||||||||||||||
Programming and Measurement (USB, LAN, GPIB) |
| ||||||||||||||||||||||||||||||
Input Characteristics |
| ||||||||||||||||||||||||||||||
Interface Capabilities |
|
Channel 3
Module Type |
| ||||||||||||||||||||||||||||
Constant Voltage Mode |
| ||||||||||||||||||||||||||||
Constant Current Mode |
| ||||||||||||||||||||||||||||
Protection Function |
| ||||||||||||||||||||||||||||
Analog Programming and Monitoring |
| ||||||||||||||||||||||||||||
Front Panel |
| ||||||||||||||||||||||||||||
Programming and Measurement (USB, LAN, GPIB) |
| ||||||||||||||||||||||||||||
Input Characteristics |
| ||||||||||||||||||||||||||||
Interface Capabilities |
|
Environmental Conditions
Operaing temperature | 0°C to 50 °C |
Storage temperature | -25°C to 70 °C |
Operating humidity | 20% to 85% RH; No condensation |
Storage humidity | 90% RH or less; No condensation |
Altitude | Maximum 2000m |
General Specifications
Weight (main unit only) | Approx. 5.4kg | ||||||
Dimensions (W×H×D) | 142 x 124 x 350 mm | ||||||
Cooling | Complies with the European EMC directive for Class A test and measurement products | ||||||
Safety | Complies with the European Low Voltage Directive and carries the CE-marking | ||||||
Withstand voltage |
| ||||||
Insulation resistance |
|
*1: At 85 ~ 132Vac or 170 ~ 265Vac, constant load.
*2: From No-load to Full-load, constant input voltage. Measured at the sensing point in Remote Sense.
*3: Measure with JEITA RC-9131B (1:1) probe
*4: Measurement frequency bandwidth is 10Hz to 20MHz.
*5: Measurement frequency bandwidth is 5Hz to 1MHz
*6: From 10% to 90% of rated output voltage, with rated resistive load
*7: From 90% to 10% of rated output voltage, with rated resistive load.
*8: Time for output voltage to recover within 0.1% + 10mV of its rated output for a load change from 50 to 100% of its rated output current
*9: For load voltage change, equal to the unit voltage rating, constant input voltage.
Do you have a Triple-Channel Programmable Switching 80V/13.5A and 2 x 160V/7.2A 1080W Multi-Range D.C. Power Supply that needs to be calibrated?
We offer standard traceable calibration and ISO 17025 accredited calibration services.
Get your Triple-Channel Programmable Switching 80V/13.5A and 2 x 160V/7.2A 1080W Multi-Range D.C. Power Supply calibrated today! Click Here!
There are currently no reviews for this product.
Recommended Accessories for the Triple-Channel Programmable Switching 80V/13.5A and 2 x 160V/7.2A 1080W Multi-Range D.C. Power Supply
USB TO RS-232 Cable (#4-40 UNC), 3000mm
Extended Terminal
USB TO RS-232 Cable, 3000mm