Overview
Features
Specifications
Calibration

GDS-200/300 series oscilloscopes, the brand new concept compact digital oscilloscopes developed by GW Instek, introduce 7” capacitive full touch panel LCD which can be positioned in portrait and landscape display. The recharging-battery design makes the series easy to operate for field operations. The GDS-200/300 series are applicable in laboratories, R&D, large electric system tests, power product tests, motor tests, solar power battery inspection and repair, and maintenance personnel who are always on field assignments.

The GDS-200/300 series, with two analog signal input channels, have advanced and standard models which come with 70MHz, 100MHz and 200MHz bandwidth. The maximum sample rate per channel is 1GSa/s and memory depth is 5Mpts. GDS-300 series oscilloscopes are equipped with 50,000 counts DMM, and GDS-200 5,000 counts DMM which can simultaneously measure and monitor A.C. and D.C. voltage and current, and temperature. Trend plot in a long period of time can also be drawn that allows engineers to effectively monitor standard electric parameters while measuring basic circuit signals.

Optional 40 MHz dual-channel differential probe can achieve equivalent isolation results for measurement system under strict power and grounding environment. Users can also easily apply the oscilloscope as a very convenient USB storage equipment to store waveform images and raw data. Additionally, the oscilloscope can be connected with smart phones to transmit the recorded data. Engineers are aware of GW Instek oscilloscopes’ thoughtful designs through diversified application software. Advanced DMM function and GO/NOGO template editing facilitate users in conducting advanced diversified measurement functions. Engineering calculator, attenuation calculation analysis, and resistance indication analysis help users apply auxiliary functions that demonstrate the concept of powerful and comprehensive technological integration.

Full Touch Panel Capacitive LCD

GDS-200/300 - Full Touch Panel Capacitive LCD 1 GDS-200/300 - Full Touch Panel Capacitive LCD 2

GDS-200/300 series oscilloscopes adopt full touch panel capacitive LCD. In the era of smart phone explosion, GW Instek can also usher users into the full touch panel measurement era. With only one finger, users not only can move waveform up and down but also the trigger line position. Two-point touch panel is also applied. Engineers can use two fingers to adjust vertical voltage level and to enlarge or narrow time division scale. The brand new touch panel and swift response renew your measurement concept. Additionally, one finger drag menu selection allows users to follow their intuition to locate required measurement functions, and to save and retrieve diagrams and data anytime anywhere.

Portrait/Landscape Display

GDS-200/300 - Portrait Display GDS-200/300 - Landscape Display

GDS-200/300 series oscilloscopes allow portrait and landscape display. Engineers have different requirements under different environments. When field test and measurement is necessary engineers often need portrait display to conduct measurement due to environment limitation and the emphasis of integrated functions. Waveform measurement and DMM can be simultaneously operated. When indoor test and measurement is required engineers often need stable measurements and large screen which is answered by landscape display. 7” full measurement screen can also be applied as a stable desk-top oscilloscope.

Simultaneous utilization of Oscilloscope and DMM

GDS-200/300 - Simultaneous utilization of Oscilloscope and DMM Traditional oscilloscopes can not meet users’ requirements of conducting integrated system circuit measurement. One extra DMM is often required to work with traditional oscilloscopes to handle enormous test requirements. GDS-200/300 series oscilloscopes integrate the functions of oscilloscope and DMM to conduct simultaneous measurements. In the analysis of system circuit waveforms, GDS-200/300 can also use DMM to measure basic voltage and current of the peripheral components that provides users with very powerful test integration.

30,000 Waveform Records Replay Function

GDS-200/300 - 30,000 Waveform Records Replay Function - 1 GDS-200/300 - 30,000 Waveform Records Replay Function - 2

GDS-200/300 series oscilloscopes have built-in 30,000 waveform records replay function. With this function, engineers can monitor circuit in a long period of time. When 30,000 waveform records are completed history records can be replayed repeatedly. Any intermittently appeared abnormal waveforms can be identified by this function which provides users with a very powerful search and debugging weapon.

Optional Differential Probe

In many strict test and measurement environments, system power isolation and grounding problem have become one of the key issues. Bad isolation and grounding will have serious impact on circuit system safety. Optional differential probe of GDS-200/300 series oscilloscopes can achieve equivalent isolation results for measurement system and there is no grounding problem. Under today’s economic constraints, using differential probe to achieve isolation result is one of the best choices.

Briefing Material Compilation

GDS-200/300 - Briefing Material Compilation - 1 GDS-200/300 - Briefing Material Compilation - 2

Engineers or students often compile briefing material for work or class requirements. The completeness and convenience of briefing often determine users’ performance. GDS-200/300 series oscilloscopes provide very strong briefing material compilation function. Before compiling briefing material, users can select different test and background conditions such as date, time and cursor. In addition, measurement parameters can also be determined based upon different requirements. This customer-made function not only shows the complete waveforms but also provides peripheral parameters to become the key communication bridge for work and class requirements.

GO/NOGO Template Editing

GDS-200/300 - GO/NOGO Template Editing - 1 GDS-200/300 - GO/NOGO Template Editing - 2

Many component or system manufacturers require GO and NOGO product analysis for quality control or production. GDS-200/300 series oscilloscopes have the same GO/NOGO function as that of GW Instek other oscilloscopes. This function establishes corresponding waveform templates based on waveforms measured to conduct GO or NOGO results calculation. Additionally, GDS-200/300 have template editing function. Users not only can edit template freely according to test or environment conditions but also set templates with different ceiling and floor boundaries, making GO/NOGO function more diversified and user-friendly.

Tools Electrical Engineers Often Applied

GDS-200/300 - Tools Electrical Engineers Often Applied - Calculator GDS-200/300 - Tools Electrical Engineers Often Applied - Attenuator Calculator GDS-200/300 - Tools Electrical Engineers Often Applied - Resistance Calculator

GDS-200/300 series oscilloscopes have built-in diversified application software to provide users with very thoughtful auxiliary tools. In the tedious circuit design process, engineering calculator software provides mathematical calculation functions from basic to advanced allowing engineers to thoroughly understand circuit response and parameter value. Resistance calculation software not only provides accurate resistance value for different surface embedded resistance codes but also color coding resistance value enquiry function. It is a very powerful auxiliary tool for users from students to senior electrical engineers.

Image Storage and Preview Function

GDS-200/300 series oscilloscopes can record screen images and preview images. In many complex test and measurement environments, when engineers can not observe images from his or her computer immediately after images were stored the image preview function allows users to make sure file is correct right away. Pre-observation operation is also very convenient to users.  GDS-200/300 - Image Storage and Preview Function

Used as USB Component

Once engineers finished waveform measurement and report compilation, GDS-200/300 series oscilloscopes can be used as USB storage component to retrieve and store files. Briefing speaking, users can use USB connecting cable to connect GDS 200/300 with the PC or handheld device to retrieve any required files for follow-up actions. Today, smart phone is ubiquitous, the screenshots and measurement results of GDS-300/200 can be transmitted via smart phone that saves a lot of troubles.

Temperature Measurement and Logging Function

GDS-300 series oscilloscopes’ built-in temperature measurement and logging function allows users to conduct systematic temperature measurement and logging for electric components and electric systems. This function can collocate with different temperature measurement probes. B,E,J,K,N,R,S,T thermal coupling measurement probes are also supported to conduct Celsius and Fahrenheit scaled temperature measurement. Users can also use trend plot editing to conduct temperature monitoring in a long period of time. It is a simple and convenient measurement tool for quality assurance and test departments.

  • 100MHz Bandwidth Selections, Two Input Channels
  • 1GSa/s Maximum Sample Rate
  • Maximum 5M Memory Depth Per Channel
  • 7” 800 x 480 Full Touch Panel Capacitive LCD Multi-Point Control, Landscape and Portrait Display
  • Built-In 5,000 Counts DMM
  • 30,000 Consecutive Waveform Records Logging Function, Replay Measurement Results Any Time
  • Logging Function
  • Built-In Engineering Calculator, SMD Resistance Coding, Color Coding Info, and Attenuator Calculation Application Software
  • Optional Differential Probe to Achieve Isolation Effect

Vertical

Channels 2 (BNC-Shield)
Input Impedance 1MΩ±2%, 16.5pf approx.
Maximum Input CAT II 300VRMS
Input Coupling AC, DC, GND
Bandwidth DC~100MHz (-3dB)
Rise time <3.5ns
Sensitivity 2mV/div~10V/div (1-2-5 increments)
Accuracy ±(3% x Readout + 0.1 div + 1mV)
Bandwidth Limit 20MHz(-3dB)
Polarity Normal, Invert
Offset Position Range 2mV/div~50mV/div : ±0.4V
100mV/div~500mV/div : ±4V
1V/div~5V/div : ±40V
10V/div : ±300V

Signal Acquisition

Realtime sample rate 1GSa/s
Memory depth 1M points per ch
Acquisition mode Average: 2~256 waveforms
Peak detect: 10ns
sin(x)/x or ET
Replay wfms. 30,000 wfms.

Trigger

Source Ch1 or Ch2
Trigger mode Auto, Normal, Single, Force
Trigger type Edge, Pulse Width, Video, Alternate
Trigger Holdoff 10ns ~ 10s
Coupling AC, DC, LFR, HFR, NR
Sensitivity DC~25MHz: approx. 0.5div or 5mV
25MHz~ 70/100/200MHz: approx. 1.5div or 15mV

Horizontal

Range 5ns~100s/Div (1-2-5 increments)
Roll 100ms/div ~ 100s/div
Pre-trigger 10 div max.
Post_trigger 1,000 div max(depend on time base)
Accuracy ±20ppm over any > 1ms time interval

XY Mode

  Phase Shift ±3° at 100KHz

Cursor and Measurement

Cursors Voltage difference between cursors(△V), Time difference between cursors(△T), frequency measure(1/△T)
Auto-measurement 36 sets.
Auto-counter 6 digits. Range: 2Hz to rated bandwidth
Autoset Available
TEMPERATURE MEASUREMENT Non-Available

Miscellaneous

Multi-Language Menu Available
On-line Help Available
Time and Clock Available

Battery

Battery power Li-polymer 6100mA/hr, 7.4V (Built-in)
Charge time 2.0 hour (75%)
Operation time 4.1 hour, depending on operating condition.

Probe Compensation

2V, 1KHz, 50% Duty cycle

Interface

USB USB Device (Isolation)
Internal Flash Disk 120MB

Display

Type 7 inch
Display resolution 480 x 800 pixels
Display direction Landscape & Portrait
Backlight control Manual adjustable, ECO mode
Touch panel Capacitive

Power Adaptor

Line Voltage AC 100V~240V, 48~63Hz, Power Consumption 40W
  DC Output: 12V/3A, Double Shield

Option

Differential Probe Dual-channel, 40MHz, CAT II 600V

Dimensions & Weight

1.5Kg,  HxWxD(mm)  240mm x 136mm x60 mm

DMM

DIGIT LEVEL 5,000 counts
CAT II 600VRMS, CAT III 300VRMS

DC VOLTAGE

Range 50mV, 500mV, 5V, 50V, 500V,  1000V  6 ranges
Accuracy 50mV, 500mV, 5V, 50V, 500V ±(0.05% + 5 digits), 1000V ±(0.1% + 5 digits) 
Input Impedance 10MΩ

DC CURRENT

Range 50mA, 500mA,  10A  3 ranges
Accuracy 50mA - 500mA, 2 Ranges, ±(0.1% + 5 digits), 10A ±(0.5% + 1 digits) 

AC VOLTAGE

Range 50mV, 500mV, 5V, 50V, 700V  5 ranges
Accuracy 50mV, 500mV, 5V, 50V, 700V ±(1.5% + 15 digits) at 50Hz-1kHz
AC CURRENT
Range 50mA, 500mA, 10A 3 ranges
Accuracy 50mA, 500mA, ±(1.5% + 15 digits) at 50Hz-1kHz 
10A ±(3% + 15 digits) at 50Hz-1kHz
  * Measure range: >10mA

RESISTANCE

Range 500Ω, 5kΩ, 50kΩ, 500kΩ, 5MΩ, 5 range
Accuracy 500Ω, 5kΩ, 50kΩ, 500kΩ ±(0.3% + 3 digits)
5MΩ ±(0.5% + 5 digits)
* Measure range: 50Ω to 5MΩ
DIODE TEST Maximum forward voltage 1.5V, Open voltage 2.8V
 
CONTINUITY BEEP < 15 Ω
 
FUNCTIONS Auto Range, Max, Min, Hold, Trend plot

Download Software


Do you have a 100MHz Compact Digital Storage Oscilloscope (full touch screen) that needs to be calibrated?

We offer standard traceable calibration and ISO 17025 accredited calibration services.

Get your 100MHz Compact Digital Storage Oscilloscope (full touch screen) calibrated today! Click Here!

 

There are currently no reviews for this product.

 

Review the GW Instek GDS-210 - 100MHz Compact Digital Storage Oscilloscope (full touch screen)

100MHz Compact Digital Storage Oscilloscope (full touch screen)

Name :

Email :

Title :

Review: