Your Cart
(empty)
0
Tradeport Electronics
measurement is our business
Cart : (empty)

Fluke TIR125-9HZ - TiR125 Building Diagnostic Thermal Imager

TiR125 Building Diagnostic Thermal Imager

Fluke

Rated 0 / 5 (0 reviews)

Category : Infrared Thermometers / Cameras

by quote only add to cart

Documents:
Datasheet

Overview
Features
Specifications
Calibration

The Fluke TiR125 Thermal Imager can save you time and money by finding potential problems and can help grow your business by offering your customers more services. With the innovative features and functionality in the Fluke TiR125 Thermal Imager and 160 x 120 resolution, you can perform infrared inspections faster and more efficiently and thoroughly document problem areas for additional follow-up.

Spend less time in the field and more time growing your business.

 

  • Exclusive IR-OptiFlex™ focus system-ensures that images are in good focus from 1.2 m (4 ft) and beyond for optimum image clarity and scanning convenience. For shorter distances change to manual mode with the touch of a finger.
  • Always have references handy-IR-PhotoNotes™ annotation system-Quickly identify and keep track of inspection locations by adding digital images of important information and surrounding areas.
  • Find problems faster and easier-IR-Fusion® with AutoBlend™ mode-Accurately identify potential issues by combining digital and IR images with AutoBlend. It blends digital and partially transparent IR images into a single information-filled image.
  • Multi-mode video recording-focus-free video in visible light and infrared with full IR-Fusion.
  • Easily communicate the location of problems with the Electronic Compass (8-Point Cardinal).

 

Detailed Specifications

Building Diagnostics

IR resolution (FPA size) 160 x 120 FPA Uncooled Microbolometer
Spectral band 7.5 µm to 14 µm (long wave)
Capture or refresh rate 9 Hz
NETD (thermal sensitivity) ≤ 0.08 °C at 30 °C target temp (80 mK)
FOV (Field of view) 22.5 °H x 31 °V
IFOV (Spatial resolution) 3.39 mRad
Temperature measurement range (not calibrated below -10 °C) -20 °C to +150 °C (-4 °F to +302 °F)
Temperature measurement accuracy ± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
Focus mechanism IR-OptiFlex™ focus system
IR-FusionR technology PIP, FULL IR, FULL VISIBLE, AutoBlend™
Color alarms High termperature, low temperature (dewpoint), and isotherm
Standard palettes Blue-Red, Grayscale, Inverted Grayscale, High-contrast, Hot Metal, Ironbow, Amber, Inverted Amber
Ultra Contrast palettes Blue-Red, Grayscale, Inverted Grayscale, High-contrast, Hot Metal, Ironbow, Amber, Inverted Amber
Hot/cold markers Yes
User definable spot markers Three on camera and in SmartView®
Centerbox (MIN/AVG/MAX) Yes
Level and span control Manual and auto
Minimum span in auto mode 2.5 °C
Minimum span in manual mode 2.0 °C
Minimum IR focus distance 15.25 cm (6 in)
Weight 0.726 kg (1.6 lb)
Size 28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in)
LCD display 3.5 inch diagonal (portrait format)
Visible camera 2 megapixel industrial-grade
Minimum parallax ~18-22 inches
IR-PhotoNotes annotation system Yes (3 images)
Laser pointer Yes
Torch Yes
Electronic (cardinal) compass Yes
Emissivity correction Yes
transmission correction Yes
Background (reflected) compensation Yes
Voice annotation (audio) Yes (60 seconds) per image
Multi-mode video output Streaming USB video output
Multi-mode video recording (standard AVI with MPEG encoding) Yes (AVI with MPEG encoding)
Multi-mode video recording (radiometric .IS3) Yes, radiometric .is3 for approx. 2.5 to 5 minutes depending upon thermal scene
Memory review thumbnail review
Battery (field-replaceable, rechargeable) Two
Battery life 4+ hours (each)*
External battery charging base Included
Charging power supply Yes
Drop test 2 meter (6.5 feet)
Ingress protection (IP) rating (IEC 60529) IP 54
Est. calibration cycle Two-years
Multifunction card reader Included
Memory storage 2 GB SD memory card
Direct download capability mini USB direct download
Operating temperature range -10 °C to +50 °C (14 °F to 122 °F)
Storage temperature range -20 °C to +50 °C (-4 °F to 122 °F)
Operating humidity Operating and storage 10 % to 95 %, non-condensing
Vibration and shock 2G, IEC 68-2-26 and 25G, IEC 68-2-29
Safety standards CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01
C Tick IEC/EN 61326-1
EMI, RFI, EMC EN61326-1; FCC Part 5
User manuals Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, traditional Chinese, Turkish, Dutch, and Hungarian
Standard warranty period Two-years
Extended warranty and service plans Yes

*Assumes 50% brightness of LCD


Do you have a TiR125 Building Diagnostic Thermal Imager that needs to be calibrated?

We offer standard traceable calibration and ISO 17025 accredited calibration services.

Get your TiR125 Building Diagnostic Thermal Imager calibrated today! Click Here!

 

There are currently no reviews for this product.

 

Review the Fluke TIR125-9HZ - TiR125 Building Diagnostic Thermal Imager

TiR125 Building Diagnostic Thermal Imager

Name :

Email :

Title :

Review: