GW Instek GDM-350A - 3 1/2 Digits Hand-Held DMM

3 1/2 Digits Hand-Held DMM

GW Instek

Rated 0 / 5 (0 reviews)

Category : Multimeters

by quote only add to cart

Documents:
Datasheet

Overview
Features
Specifications
Calibration

The GDM-300/400 Series Hand Held DMM are a compact, high precision, battery operated multimeter series designed to meet most of the daily needs for design engineers as well as service engineers. The GDM-300/400 series design is driven by mobile-oriented features, such as automatic power down to preserve battery life, a large backlight display for crisp viewing, a rotary selector switch and clear-cut push buttons to ease operation. The basic functions match the depth of bench-top multimeters: fuse-protected current input, true RMS for accurate AC measurements, Auto ranging, Duty cycle, and Relative mode. These compact, reliable, and economical devices are ideal for any engineer.

This product has been discontinued. Our replacement recommendation is the GDM-350B - GW Instek 3 1/2 Digits Hand-Held DMM

  • 3 1/2 Digits 1999 counts
  • Manual Ranging
  • Continuity Beeper/Diode Test
  • Data Hold
  • Temperature Measurement
  • Capacitance, Frequency Measurement

 

DC VOLTAGE

Range

220mV, 2.2V, 22V, 220V, 1000V(GDM-461); 200mV, 2V, 20V, 200V, 1000V(GDM-451/356)

40mV, 400mV, 4V, 40V, 400V, 1000V(GDM-397); 400mV, 4V, 40V, 400V, 1000V(GDM-394/396)

400mV, 4V, 40V, 400V, 600V(GDM-395); 200mV, 2000mV, 20V, 200V, 250V(GDM-350B)

Best Accuracy

±(0.1%rdg + 2 digits) for GDM-461; ±(0.05%rdg + 3 digits) for GDM-451

±(0.5%rdg + 1 digit) for GDM-397/356; ±(0.8%rdg + 1 digit) for GDM-394/396

±(0.7%rdg + 3 digits) for GDM-395; ±(0.5%rdg + 2 digits) for GDM-350B

Input Impedance

10 MΩ (3000MΩ for mV range of GDM-461/397)

AC VOLTAGE

Range

220mV, 2.2V, 22V, 220V, 750V(GDM-461); 2V, 20V, 200V, 750V(GDM-451/356)

40mV, 400mV, 4V, 40V, 400V, 750V(GDM-397); 4V, 40V, 400V, 750V(GDM-394/396)

4V, 40V, 400V, 600V(GDM-395); 200V, 250V(GDM-350B)

Best Accuracy

±(0.8%rdg + 10 digits) for GDM-461; ±(0.5%rdg + 10 digits) for GDM-451

±(1.0%rdg + 3 digits) for GDM-397; ±(1.0%rdg + 5 digits) for GDM-394/396

±(0.8%rdg + 3 digits) for GDM-356; ±(2.3%rdg + 5 digits) for GDM-395

±(1.2%rdg + 3 digits) for GDM-350B

Input Impedance

10 MΩ (3000MΩ for mV range of GDM-461/397; 4.5MΩ for GDM-350B; 2MΩ for GDM-451)

DC CURRENT

Range

220µA, 2200µA, 22mA, 220mA, 10A(GDM-461); 2mA, 20mA, 200mA, 20A(GDM-451)

400µA, 4000µA, 40mA, 400mA, 4A,10A(GDM-397); 2000µA, 20mA, 200mA, 10A(GDM-350B)

400µA, 4mA, 40mA, 400mA, 4A,10A(GDM-394/396); 20mA, 200mA, 20A(GDM-356)

Best Accuracy

±(0.5%rdg + 10 digits) for GDM-461; ±(0.5%rdg + 5 digits) for GDM-451

±(1.0%rdg + 2 digits) for GDM-397/394/396/350B; ±(0.8%rdg + 1 digit) for GDM-356

AC CURRENT

Range

220µA, 2200µA, 22mA, 220mA, 10A(GDM-461); 20mA, 200mA, 20A(GDM-451/356)

400µA, 4000µA, 40mA, 400mA, 4A,10A(GDM-397)

400µA, 4mA, 40mA, 400mA, 4A,10A(GDM-394/396)

Best Accuracy

±(0.8%rdg + 10 digits) for GDM-461/451; ±(1.2%rdg + 5 digits) for GDM-397

±(1.5%rdg + 5 digits) for GDM-394/396; ±(1.0%rdg + 3 digits) for GDM-356

RESISTANCE

Range

220Ω ~ 220MΩ 7 ranges(GDM-461); 200Ω ~ 200MΩ 7 ranges(GDM-451/356)

400Ω ~ 40MΩ 6 ranges(GDM-394/395/396/397); 200Ω ~ 20MΩ 6 ranges(GDM-350B)

Best Accuracy

±(0.5%rdg + 10 digits) for GDM-461; ±(0.3%rdg + 1 digit) for GDM-451

±(1.0%rdg + 2 digits) for GDM-394/396/397; ±(2.0%rdg + 5 digits) for GDM-395

±(0.8%rdg + 1 digit) for GDM-356; ±(0.8%rdg + 5 digits) for GDM-350B

CONTINUITY BEEPER

Buzzer sounds if conductance less than 70Ω for GDM-451/394/395/396/356

Buzzer sounds if conductance less than 10Ω for GDM-461/397/350B

DIODE TEST

Open Circuit Voltage

GDM-461/451/397/356 : 2.8V(Approx.); GDM-394/395/396 : 1.48V(Approx.)

GDM-350B : 2.3V(Approx.)

CAPACITANCE

Range

22nF, 220nF, 2.2µF, 22µF, 220µF, 2.2mF, 22mF, 220mF(GDM-461)

40nF, 400nF, 4µF, 40µF, 400µF, 4000µF(GDM-397); 2nF, 20nF, 2µF, 20µF(GDM-451)

40nF, 400nF, 4µF, 40µF, 100µF(GDM-394/395/396); 20nF, 200nF, 2µF, 100µF(GDM-356)

Best Accuracy

±(3.0%rdg + 5 digits) for GDM-461/397/396/394; ±(3.0%rdg + 40 digits) for GDM-451

±(5.0%rdg + 10 digits) for GDM-395; ±(4.0%rdg + 3 digits) for GDM-356

FREQUENCY

Range

10Hz ~ 220MHz(GDM-461); 1Hz ~ 20kHz(GDM-451/356)

10Hz ~ 10MHz(GDM-394/396/397); 1Hz ~ 99.9kHz(GDM-395)

Best Accuracy

±(0.01%rdg + 5 digits) for GDM-461; ±(1.5%rdg + 5 digits) for GDM-451/356

±(0.1%rdg + 3 digits) for GDM-394/396; ±(0.1%rdg + 4 digits) for GDM-397

±(0.7%rdg + 3 digits) for GDM-395

TEMPERATURE

Range

-40ºC ~ 1000ºC

Best Accuracy

±(1.0%rdg + 30 digits) for GDM-451; ±(1.0%rdg + 7 digits) for GDM-396/356

±(1.2%rdg + 4 digits) for GDM-397; ±(1.0%rdg + 3 digits) for GDM-350B

SPECIAL FUNCTION

Auto Ranging(GDM-461/397/396/395/394); True RMS(GDM-461/396); RS-232C(GDM-461/397/396)

hFE Test(GDM-461/350B); Display Backlight(GDM-451/397/396/394/356); Analogue Bar(GDM-461/397)

LCD DISPLAY

22000 counts(GDM-461), 4 1/2 digits(GDM-451),

3 3/4 digits(GDM-397/396/395/394), 3 1/2 digits(GDM-356/350B)

POWER SOURCE

Single 9V Battery (6F22), Cell Battery for GDM-395 (CR2032)

DIMENSIONS & WEIGHT

87(W) x 180(H) x 47(D) mm, Approx. 370g (GDM-461/397)

85(W) x 177(H) x 40(D) mm, Approx. 330g (GDM-396/394)

80(W) x 165(H) x 38.3(D) mm, Approx. 275g (GDM-451/356)

72(W) x 137(H) x 35(D) mm, Approx. 200g (GDM-350B)

56(W) x 110(H) x 11.5(D) mm, Approx. 97g (GDM-395)


Do you have a 3 1/2 Digits Hand-Held DMM that needs to be calibrated?

We offer standard traceable calibration and ISO 17025 accredited calibration services.

Get your 3 1/2 Digits Hand-Held DMM calibrated today! Click Here!

 

There are currently no reviews for this product.

 

Review the GW Instek GDM-350A - 3 1/2 Digits Hand-Held DMM

3 1/2 Digits Hand-Held DMM

Name :

Email :

Title :

Review: