Time Electronics 5030 - Electrical Tester Calibrator

Electrical Tester Calibrator

Time Electronics

Rated 0 / 5 (0 reviews)

Category : Electrical Testers

by quote only add to cart

Documents:
Datasheet

Overview
Features
Specifications
Calibration

A precision instrument designed to calibrate RCD, loop, insulation, earth testers and multifunction installation testers. The 5030 accurately simulates RCD trip times and measures currents produced by RCD testers. It replicates loop impedance and auto adjusts for local line impedance. It also provides insulation resistances and measures test voltages and currents.

Simple Operation and Automated Calibration

User control is via the central navigation keypad. Scrolling though menus and settings is intuitive and easy, with measurements and settings shown on the large clear LCD display. Alternatively connect the 5030 to a PC/laptop (via RS232 or USB) installed with Time Electronics’ EasyCal software and automate the calibration process. Increase speed of calibration and consistency of results. Easily produce calibration certificates and reports to ISO 9001, ISO 17025, and other international quality standards.

Regional Test Sockets and Fault Detection

For loop and RCD tests the electrical tester (device under test) connects directly to the dedicated front panel mains socket. The 5030 can be fitted with a number of regional type sockets (specified on order). In these test conditions, if the device under test is faulty, the 5030 auto detects the fault, disconnects the output and warns the user. The 5030 is designed not to trip any RCDs on the local supply.

Loop Impedance with Auto Local Loop Measurement

With 10 measurement points the 5030 covers a wide range of loop testers. The precision resistors that make up the loop calibration function are high power and capable of withstanding up to 30A. An accurate automatic measurement of the local loop is made by the 5030 and added to the resistor value to give the loop impedance value, allowing for precise loop impedance calibration.

Precise RCD Trip Times

RCD trips can be simulated from 10 to 2000ms in duration. The trip time can be set to predefined values for quick selection, or to a user time via the front panel.

RCD Current Measurements

Current measurement is made of the applied RCD test current. Current measurements are true RMS for AC, half wave rectified as well as being able to measure DC tests. The ranges covered are from 6mA to 1000mA, with multipliers of x0.5, x1, x2, and x5 up to a maximum of 2500mA. To avoid false current measurements the 5030 incorporates a ‘pre-test delay’ setting. This feature is for use with RCD testers that produce a pre-test signal. A test current threshold setting (0 to 100% of nominal current) is also user selectable.

Insulation Resistance and Test Voltage Measurement

The 5030 tests the functions of megohm meters using precision high value resistors up to 2GΩ. Resistance value can be set via front panel or via remote control to allow many test points to be automated. Voltage measurement functions allow accurate test voltages up to 1kV to be measured whilst under 0.5mA or 1mA test conditions.

Continuity and Earth Resistance

The 5030 precision low ohm resistors allow calibration of continuity functions found on most multifunction testers and insulation testers. Applied test voltages and currents are also measured.

Mains Voltage and Frequency

The local mains supply voltage and frequency is precisely measured by the 5030. This is used to cross reference the voltage reading on the unit under test and confirm the instruments accuracy. 

  • RCD: 3 - 2500mA, 10 - 2000ms
  • Loop 50mΩ to 1.8kΩ
  • Insulation up to 2GΩ / 1kV
  • Continuity 0.1Ω to 10kΩ
  • RS-232 / USB Control
  • Fast and intuitive user interface
  • EasyCal software compatible

 

Loop

Function Range / Values Resolution Accuracy

Loop Impedance 
Resistor Values

1800, 330.0, 180.0, 33.00, 18.00, 3.300, 
1.800, 0.330, 0.150 and 0.050Ω

4 digit

±0.5% of displayed value ± 30mΩ

Local Loop Compensation

0 to 9.999Ω

0.001Ω

±0.5% of value ± 30mΩ

Test Current

30A max (200ms) / 50W max

RCD

Function Range / Values Resolution Accuracy

Trip Time

10 to 2000ms

1ms

±0.5ms

Current

6.000, 10.00, 30.00, 100.0, 300.0, 500.0, 1000mA

4 digit

±0.5% of reading. ±1% with x5 multiplier

Current Multipliers x0.5, x1, x2, x5
Maximum Current 2500mA
Waveforms AC, DC, half wave rectified
Phase Detection 0° or 180°

Pre Trigger Delay

0 to 2000ms

10ms

Pre Trigger Threshold

0 to 100% of nominal current

1%

Insulation

Function Range / Values Resolution Accuracy

Resistance

1MΩ to 2000MΩ 
50kΩ to 1990kΩ

1MΩ 
50kΩ

1% of value
1% of value

Test Voltage Measurement 
@ 0.5mA or 1.0mA Load 

50.0 to 99.9V DC 
100 to 1200V DC 

0.1V
1V

1% of reading
1% of reading

Continuity

Function Range / Values Resolution Accuracy

Resistance

0.1Ω to 100.0Ω 
250Ω, 500Ω, 1.00kΩ, 2.50kΩ, 5.00kΩ & 10.0kΩ

0.1Ω 
3 digit

1% of value + 20mΩ
1% of value

Test Voltage Measurement 
(input resistance 10MΩ)

0.0 to 50.0V DC

0.01V

0.5% of range

Test Current Measurement 
(between 1Ω and 2Ω)

0 to 400mA DC

0.1mA

0.5% of range

Power Dissipation 1 watt maximum

Voltage

Function Range Resolution Accuracy

Line Voltage Measurement

200.0 to 260.0V RMS

0.01V

0.5% of reading

Line Frequency Measurement 45.00 to 65.00Hz 0.01Hz 0.1% of reading

General Specifications

Warm up 30 minutes to full accuracy
Settling Time Less than 5 seconds
Standard Interfaces RS-232 and USB

Temp Performance

Operating: 10 to 35°C, Full Spec: 23°C ±5°C, Storage: -10°C to 50°C

Operating Humidity < 80% non condensing
Operating Altitude 0 to 3km. Non operating: 3km to 12km
Line Power 220 - 240V AC 50Hz. Power Consumption 200W max
Dimensions W430mm x H155mm x D255mm
Weight 8kg
Country of Origin UK
Supplied With User manual, RS-232 cable, USB adaptor/cable

Do you have a Electrical Tester Calibrator that needs to be calibrated?

We offer standard traceable calibration and ISO 17025 accredited calibration services.

Get your Electrical Tester Calibrator calibrated today! Click Here!

 

There are currently no reviews for this product.

 

Review the Time Electronics 5030 - Electrical Tester Calibrator

Electrical Tester Calibrator

Name :

Email :

Title :

Review: