Test Products International 708 - TPI Model Combustion Effincy Analyzer
The carbon monoxide sensor used in TPI combustion efficiency analyzers feature an on-board filter capable of filtering NO (nitric oxide), NO2 (nitrogen dioxide) and NOX (combination of NO and NO2) to prevent cross sensitivity errors.
Use TPI analyzers to test flue gases in gas and oil fired equipment including high efficiency furnaces and condensing boilers. Measure CO, O2, and stack temperature.
Determine combustion efficiency, CO2, and CO air free. Some models include built-in differential manometer, combustible gas detection, PC communication, data logging, and can measure NO / NOX.
- Measure CO, and temperature
- Calculate CO2, efficiency, excess air, and CO air free
Model 708 Features
Using TPI analyzers to determine combustion efficiency at the time of equipment set up minimizes call backs and can be used to verify to the home owner the value of service work by showing the increase in equipment efficiency after work is performed. Efficiency calculation can also be used to generate business by demonstrating the need to improve the efficiency of equipment or to show the benefit of purchasing new equipment with higher efficiency.
| Model 708 Specifications | ||
|---|---|---|
| Carbon Monoxide (CO) Measurement |
Range 0 to 10,000 ppm Resolution 1 ppm Accuracy +/-5ppm or 5% of reading whichever is greater |
|
| Oxygen (02) Measurement | Range 0 to 25% Resolution 0.1% Accuracy ±0.3% |
|
| Carbon Dioxide (CO2) | Range 0 to 25% Resolution 0.1% Calculated Value |
|
| Nitric Oxide Measurement | N/A | |
| NOX Measurement | N/A | |
| Temperature Measurement | Range -40 to 1472°F, or -40 to 800°C Resolution 1°F or °C Accuracy (K-type) ±0.3%, ±2°F or ±1°C |
|
| Draft/Pressure Measurement |
Selectable Ranges mBar,kPa, and inH2O Ranges -150 mBar to +150 mBar -15 kPa to +15 kPa -60 inH2O to +60 in H20 Resolution 0.001 inH2O Accuracy ±0/5% fsd |
|
| Gross/Net Efficiency | Range 0 to 100% Resolution 0.1% Calculated Value |
|
| CO/CO2 Ratio | Range 0 to 0.999 Resolution 0.001 Calculated Value |
|
| Operating Temperature | 14°F to 122°F (-10°C to 50°C) | |
| Battery Type | 1.5V AA (3) | |
| Selectable Fuels | Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood, Bagasse |
|
| Display Type | Backlit 3 line LCD | |
| Data Storage | 50 Locations | |
| Data Logging | N/A | |
| Print Capability | Yes, via optional IR printer (A740) | |
| PC Communication | N/A | |
| Date and Time Function | 24 Hour Real Time Clock | |
| Dimensions | 200mm x 90mm x 60mm | |
| Weight | 500g | |
| Conformity | BS7927 (and the draft BS7967) | |
Do you have a TPI Model Combustion Effincy Analyzer that needs to be calibrated?
We offer standard traceable calibration and ISO 17025 accredited calibration services.
Get your TPI Model Combustion Effincy Analyzer calibrated today! Click Here!
There are currently no reviews for this product.
Recommended Accessories for the TPI Model Combustion Effincy Analyzer
![]()
Mini pump protection filter
![]()
Rubber Boot
![]()
Carrying Case