Test Products International 715K3 - Gas Compression Engine Service Kit High CO (above 10,000ppm carbon monoxide) Combustion Analyzer with Built-in Differential Thermometer, Differential Manometer, and NO Measurement & NOX Calculation
Overview
Features
Specifications
Calibration
The carbon monoxide sensor used in TPI combustion efficiency analyzers feature an on-board filter capable of filtering NO (nitric oxide), NO2 (nitrogen dioxide) and NOX (combination of NO and NO2) to prevent cross sensitivity errors.
- Use TPI analyzers to test flue gases in gas and oil fired equipment including high efficiency furnaces and condensing boilers. Measure CO, O2, and stack temperature.
- Determine combustion efficiency, CO2, and CO air free. Some models include built-in differential manometer, combustible gas detection, PC communication, data logging, and can measure NO / NOX.

- Measure up to 9.999% CO
- Built-in differential thermometer
- Measure NO (Nitric Oxide), Calculate NOx
- Store function to save up to 10 readings
- Calculates combustion efficiency
- Pump driven for fast response
- Push on fittings for fast and easy use
- Large easy to read backlit display
- Will not shut off if 15 ppm CO is present for increased safety
- Four selectable fuels: Natural Gas, LPG, Light Oil, Heavy Oil
| Model 715K3 Specifications | ||
|---|---|---|
| Carbon Monoxide (CO) Measurement | Range 0 to 9.999% Resolution .001% Accuracy +/-5ppm or 5% of reading whichever is greater |
|
| Oxygen (02) Measurement | Range 0 to 25% Resolution 0.1% Accuracy ±0.3% |
|
| Carbon Dioxide (CO2) | Range 0 to 25% Resolution 0.1% Calculated Value |
|
| Nitric Oxide Measurement | Range 0 to 5,000ppm Resolution 1ppm Accuracy <100ppm: ±5ppm <1000ppm ±5% >1000ppm: ±10ppm |
|
| NOX Measurement | Range 0 to 5,250 Resolution 1ppm Calculated Value |
|
| Temperature Measurement | Range -40 to 1472°F, or -40 to 800°C Resolution 1°F or °C Accuracy (K-type) ±0.3%, ±2°F or ±1°C |
|
| Draft/Pressure Measurement | Selectable Ranges mBar,kPa, and inH2O Ranges -150 mBar to +150 mBar -15 kPa to +15 kPa -60 inH2O to +60 in H20 Resolution 0.001 inH2O Accuracy ±0/5% fsd |
|
| Gross/Net Efficiency | Range 0 to 100% Resolution 0.1% Calculated Value |
|
| CO/CO2 Ratio | Range 0 to 0.999 Resolution 0.001 Calculated Value |
|
| Combustible Gas Level Indication | Yes (For flue gasses) | |
| Operating Temperature | 14°F to 122°F (-10°C to 50°C) | |
| Charger Input Voltage | 110V to 230V (50/60Hz) | |
| Selectable Fuels | Natural Gas, LPG, Light Oil, Heavy Oil | |
| Display Type | Backlit 3 line LCD | |
| Data Storage | 10 Locations | |
| Data Logging | N/A | |
| Print Capability | Yes, via optional IR printer (A740) | |
| PC Communication | N/A | |
| Date & Time Function | 24 Hour Real Time Clock | |
| Dimensions | 200mm x 90mm x 60mm | |
| Weight | 500g | |
| Conformity | BS7927 (and the draft BS7967) | |
Do you have a Gas Compression Engine Service Kit High CO (above 10,000ppm carbon monoxide) Combustion Analyzer with Built-in Differential Thermometer, Differential Manometer, and NO Measurement & NOX Calculation that needs to be calibrated?
We offer standard traceable calibration and ISO 17025 accredited calibration services.
Get your Gas Compression Engine Service Kit High CO (above 10,000ppm carbon monoxide) Combustion Analyzer with Built-in Differential Thermometer, Differential Manometer, and NO Measurement & NOX Calculation calibrated today! Click Here!
There are currently no reviews for this product.
Recommended Accessories for the Gas Compression Engine Service Kit High CO (above 10,000ppm carbon monoxide) Combustion Analyzer with Built-in Differential Thermometer, Differential Manometer, and NO Measurement & NOX Calculation
![]()
Flow Regulator
![]()
Carrying Case
![]()
Rubber Boot