Versatile and rugged tool for applications with high currents

Confidently take reliable readings with the True-rms, Fluke 353 digital clamp meter; the tools of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.

Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads.

 

  • Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms, 1400 A ac, and 2000 A dc
  • The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors
  • CAT IV 600 V, CAT III 1000 V rating for added user protection
  • In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability
  • Accurately measure frequency up to 1 kHz for optimum troubleshooting
  • Quickly analyze readings using the MIN, MAX, and AVG functions
  • A large backlit display allows for easy visibility in low-lit areas
  • Use the display hold feature to capture readings even when the display cannot be viewed
  • Use the low-pass filter to smooth out noisy loads and stabilize readings

 

Electrical Specifications
Current measurement dc and ac 10 Hz to 100 Hz Range 40 A / 400 A / 2000 A; 1400 ac rms
Resolution 10 mA / 100 mA / 1 A
Accuracy A: 1.5 % rdg + 15 digits
A: 1.5 % rdg + 5 digits
Trigger Level for Inrush 0.50 A / 5.0 A / 5 A
Trigger Level for Hz Filter OFF 2.50 A / 2.5 A / 8 A
Trigger Level for Hz Filter ON 0.50 A / 2.5 A / 8 A
Crest Factor (50/60 Hz) Range 40 A / 400 A / 2000 A; 1400 ac rms
Crest Factor* 2 @ 33 A, 2.4 @ 27 A
2 @ 330 A, 2.4 @ 270 A
2 @ 1000 A, 2.4 @ 833 A
Current measurement ac 100.1 Hz to 1 kHz Range 40 A / 400 A / 2000 A; 1400 ac rms
Resolution 10 mA / 100 mA / 1 A
Accuracy 10 A : 3.5 % rdg + 15 digits
10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush 0.50 A / 5.0 A / 5 A
Trigger Level for Hz Filter OFF 2.50 A / 2.5 A / 8 A
Trigger Level for Hz Filter ON 0.50 A / 2.5 A / 8 A
Frequency measurement Measurement range 5.0 Hz to 1 kHz
Resolution 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)
Accuracy – 5.0 Hz to 100 Hz 0.2 % + 2 counts
Accuracy – 100.1 Hz to 1 kHz 0.5 % + 5 counts
Trigger level Refer to current and voltage tables

*Add 2 % to error spec for CF > 2

General Specifications
Batteries Six 1.5 V AA NEDA 15 A or IEC LR6
Battery life (with typical usage, backlight off) 100 hours
Test leads Rated to 1000 V
Weight .814 kg (1.8 lb)
Jaw size 58 mm (2.28 in)
Dimensions (LxWxD) 300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in)
Safety rating IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III
Environmental Specifications
Operating temperature 32 °F to + 122 °F (0 °C to +50 °C)
Storage temperature -4 °F to 140 °F (-20 °C to +60 °C)
Operating humidity 0 to 95 % (non-condensing)
Operating altitude 2000 m
Storage altitude 10,000 m
IP rating 42 (indoor use only)
Drop test requirements 1 m
EMI, RFI, EMC FCC part 15, IEC/EN 61326-1:1997 class B
IEC/EN 61326:1997 3V/m, performance criteria B, EN61325
Temperature coefficients Current 0.1 % of reading per °C outside 22 °C to 24 °C
Voltage 0.1 % of reading per °C outside 22 °C to 24 °C

Do you have a True-rms 2000 A Clamp Meter that needs to be calibrated?

We offer standard traceable calibration and ISO 17025 accredited calibration services.

Get your True-rms 2000 A Clamp Meter calibrated today! Click Here!

 

There are currently no reviews for this product.

 

Review the Fluke 353 - True-rms 2000 A Clamp Meter

  True-rms 2000 A Clamp Meter

Name :

Email :

Title :

Review: