Your Cart
(empty)
0
Tradeport Electronics
measurement is our business
Cart : (empty)

Fluke 419D - Laser Distance Meter

  Laser Distance Meter

Fluke

Rated 0 / 5 (0 reviews)

Category : Other Instruments

by quote only add to cart

Documents:
Datasheet

Overview
Features
Specifications
Calibration

 The Fluke 419D laser distance meter extends your reach up to 80 meters (260 feet) with even greater accuracy. It saves you time and reduces errors with enhanced features like storage for 20 complete displays and a tripod mode for stable, long-distance measurements.

The 419D distance meters offer these enhanced features:

  • Measure up to 80 m (260 ft)
  • Higher accuracy: +/-1 mm (0.04 in)
  • View more data with backlit, three-line display
  • Full Pythagoras function for height measurements
  • Storage of 20 complete displays for quick recall
  • Audible keypad feedback
  • Minimum/Maximum function
  • Tripod mode for mounting meter on a tripod when measuring long distances
  • Stake Out feature helps you mark out defined lengths such as when constructing wooden frames
  • Automated End-piece Correction for measuring from an edge or corner – a built-in sensor detects the position of this bracket and automatically changes the reference point
  • Enhanced environmental protection: IP54-rated as dust and water spray resistant
  • Improved battery life of 5000 measurements with auto laser off and auto power off features

Like all new Fluke laser distance meters, the 419D offers instant, one-button measurement of the distance between two objects plus:

  • Bright laser for easy targeting
  • Quick calculations of area (square feet/meters) and volume
  • Easy-to-use addition and subtraction function
  • Carrying pouch secures to tool belt

All meters offer:

  • Reduction of estimation errors, saving both time and money
  • The most advanced 2 laser technology for distance measurement
  • Instant measurement with one-button operation
  • Easy addition and subtraction function
  • Quick calculation of area (square footage) and volume
  • Easy addition and subtraction of measurements
  • Minimum/maximum function
  • Improved battery life from automatic shut-off feature
  • Pythagoras calculation for determining distance indirectly from two other measurements
  • Pouch with Fluke logo
  • Three-year warranty

The 419D additionally offers:

  • Improved visibility with backlit screen
  • Ability to measure up to 80 m (260 ft) for 419D
  • Tripod mode allows you to mount to a tripod for measuring long distances
  • Stake out function
  • Enhanced Pythagoras calculation for determining distance indirectly from three other measurements
  • Audible keypad feedback
  • Storage of the last twenty measurements for quick recall of distance
  • Strong environmental protection with IP54 (water spray and dust proof) sealing

 

Distance Measurement
Typical measuring tolerance [1] ± 1.0 mm [3]
Maximum measuring tolerance [2] ± 2.0 mm [3]
Range at Leica Target Plate GZM26 80 m / 260 ft
Typical range [1] 80 m / 260 ft
Range at unfavorable condition [4] 60 m / 195 ft
Smallest unit displayed 6 / 30 / 60 mm
(10 / 50 / 100 m)
Ø Laser point at distances 6 / 30 / 60 mm
(10 / 50 / 100 m)
Tilt measurement
Measuring tolerance to laser beam [5] No
Measuring tolerance to housing [5] No
Range No
General
Laser class 2
Laser type 635 nm, <1 mW
Protection class IP54
Automatic laser off After 90 seconds
Automatic power off After 180 seconds
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 Up to 5,000 measurements
Size (length x width x depth) 127mm x 56mm x 33mm
Weight (with batteries) 153 g
Temperature range
Storage operation
-25 °C to +70°C (-13 °F to +158 °F)
-10 °C to +50 °C (14 °F to +122 °F)
Calibration cycle Not applicable
Maximum altitude 3000 m
Maximum relative humidity 85% at 20 °F to 120 °F (-7 °C to 50 °C)
Safety IEC Standard No. 61010-1:2001
EN60825-1:2007 (Class II)
EMC EN 55022:2010
EN 61000-4-3:2010
EN 61000-4-8:2010

[1] Applies for 100 % target reflectivity (white painted wall), low background illumination, 25 °C.
[2] Applies for 10 to 500 % target reflectivity, high background illumination, -10 °C to +50 °C.
[3] Tolerances apply from 0.05 m to 10 m with a confidence level of 95 %. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m.
[4] Applies for 100 % target reflectivity, background illumination between 10'000 lux and 30'000 lux.
[5] After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°.


Do you have a Laser Distance Meter that needs to be calibrated?

We offer standard traceable calibration and ISO 17025 accredited calibration services.

Get your Laser Distance Meter calibrated today! Click Here!

 

There are currently no reviews for this product.

 

Review the Fluke 419D - Laser Distance Meter

  Laser Distance Meter

Name :

Email :

Title :

Review: