Fluke 718EX-300 - Intrinsically Safe Pressure Calibrator

Intrinsically Safe Pressure Calibrator

Fluke

Rated 0 / 5 (0 reviews)

Category : Pressure Calibrators

by quote only add to cart

Documents:
User's Manual

Overview
Features
Specifications
Calibration

Pump Up the Pressure

TheFluke 718Ex 300G Intrinsically Safe Pressure Calibrator is a powerful intrinsically safe, self contained pressure calibrator for usage in explosion endangered areas.

 

  • ATEX II 1G Ex ia IIC T4 Compliant
  • Built-in pressure / vacuum hand pump, with fine adjust vernier and bleed valve
  • 300 psi ranges (20 bar)
  • Pressure measurement to 0.05% of full span, using an internal pressure sensor
  • Pressure measurement to 200 bar using any of eight intrinsically safe Fluke 700PEx Pressure Modules
  • Wide range of selectable measurement units for pressure
  • Current measurement with 0.02% accuracy and 0.001 mA resolution
  • Pressure switch test function
  • Min-Max Hold functions
  • Compact size and weight
  • Simple, push-button user interface
  • Rugged and reliable, ideal for field use

 

Measurement Accuracy
Pressure
Range -830 mbar to 20 bar (internal sensor)
  Over pressure: 375 psi, 25 bar
Resolution 0.0001 bar
Accuracy 0.05% FS
Functions Zero, min, max, hold, damp
  Note for use with non-corrosive gasses
Technical Data
Measure accuracy
Range 0-24 mA
Resolution 0.001 mA
Accuracy 0.05% rdg ± 2 counts
Display LCD, 5 digit pressure and current simultaneous
Environmental Specifications
Operating temperature -10ºC to 55ºC
Storage temperature -40ºC to 60ºC
Humidity (without condensation)

95% (10ºC to 30ºC)

75% (30ºC to 40ºC)

45% (40ºC to 50ºC)

35% (50ºC to 55ºC)

Operating altitude 3,000 m max
Safety Specifications
Safety

ATEX II 1G Ex ia IIC T4 compliant

CSA Certification I.S. Class I,

Div 1 Groups A-D , T4

Mechanical and General Specifications
Size 216 mm L x 94 mm W x 66 mm H (with holster)
Weight Approx. 992 g (with holster)
Warranty Three years, one year for pump
Shock 1 meter drop test
Vibration Random, 2 G, 5-500 Hz
Battery type One 9-volt alkaline battery ANSI/NEDA 1604A or IEC 6LR619V

Battery life: 4 to 20 hours, depending on functions used


Do you have a Intrinsically Safe Pressure Calibrator that needs to be calibrated?

We offer standard traceable calibration and ISO 17025 accredited calibration services.

Get your Intrinsically Safe Pressure Calibrator calibrated today! Click Here!

 

There are currently no reviews for this product.

 

Review the Fluke 718EX-300 - Intrinsically Safe Pressure Calibrator

Intrinsically Safe Pressure Calibrator

Name :

Email :

Title :

Review: