Fluke 87-5/E2-KIT - Industrial Electrician Combo Kit
This new combo kit is based on the Fluke 87V and includes special accessories to make industrial troubleshooting even more productive. Save over 15% compared with the individual purchase price of all the accessories.
Includes:
- 87V Multimeter
- TL224 silicone test leads
- AC220 long reach alligator clips
- TP238 test probes
- TPAK ToolPak™ Magnetic Meter Hanging Kit
- 80BK temperature probe
- C35 lightweight soft accessory case
- 9V battery (installed)
Fluke 87V Features :
- Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment
- Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument
- Optional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks
- Large digit display with bright, two-level backlight makes the 87V significantly easier to read than older models
- True-rms ac voltage and current for accurate measurements on non linear signals
- Selectable filter for accurate voltage and frequency measurements on motor drives
- 0.05 % dc accuracy
- 6000 counts, 3-3/4 digits
- 4-1/2 digit mode for precise measurements (20,000 counts)
- Measure up to 1000 V ac and dc
- Measure up to 10 A, 20 A for up to 30 seconds
- Built in thermometer lets you carry one less tool (TC probe included)
- Frequency to 200 kHz and % duty cycle
- Resistance, continuity and diode test
- 10,000 µF capacitance range for components and motor caps
- Min/Max-Average recording with Min/Max Alert to capture variations automatically
- Peak capture to record transients as fast as 250 µs
- Relative mode to remove test lead interference from low ohms measurements
- Auto and manual ranging for maximum flexibility
- Touch Hold to capture stable readings avoiding noisy signals
- Large display digits and two-level bright white backlight for increased visibility
- Analog bargraph for fast changing or unstable signals
- Input Alert provides audible warning against wrong use of input jacks
- Improved selectable sleep mode for long battery life
- Access door for fast battery changes without breaking the calibration seal
- "Classic" design with new removable holster with built in test lead and probe storage
- Lifetime warranty
Electrical safety
All inputs are updated to the 3rd edition of ANSI/ISA S82.01 and EN61010-1 CAT IV 600V and CAT III, 1000 V. They can withstand impulses in excess of 8.000 V and reduce risks related to surges and spikes.
Correctly measure pulse-width modulated motor drive signals
Until now, there hasn't been a multimeter able to accurately measure adjustable speed drives. But the Fluke 87V is designed specifically to handle these complex signals. Think of the potential productivity you'll gain by taking the guesswork out of drive system troubleshooting. Measurements are correct each and every time.
- Unique function for accurate measurements of noisy pulse-width modulated AC voltage. Measures correctly at the ASD and at the motor terminals
- Accurately measure the frequency (motor speed). Frequency measurement not affected by the ASDs carrier frequency
- Measure AC current with an optional current clamp accessory
- Compare reading from the 87V with the display on the ASD
- Special shielding blocks high frequency, high-energy noise generated by large drive systems
TL224 SureGripTM silicone test lead features:
- DMM test leads (red, black) with safety shrouded, standard diameter banana plugs
- Right angle connector on one end and straight connector on the other
- Reinforced strain relief
- 1.5 meter silicone-insulated wire resists heat & cold
- CAT IV 600 V, CAT III 1000 V, 10 A rating. UL listed
- One year warranty
AC220 SureGripTM Alligator Clips features:
- One pair (red, black) of small, insulated, nickel plated jaws
- Blunt tip grabs round screw heads up to 9.5 mm
- Recommended for use with TL222 and TL224 test leads
- CAT IV 600 V, CAT III 1000 V, 10 A rating. UL listed
- One year warranty
Fluke TP238 SureGripTM Test Lead features:
- Conforms to safety standard EN/IEC 61010-031:2002 + A1:2008, CAT III 1000 V, CAT IV 600 V
- 10 A maximum, Pollution Degree 2, 3000m altitude
- Temperature: -20C to 55C, 90% RH
- One - year warranty
- Probe tip: 4mm (0.16in)
- Flexible finger barrier improves grip
80BK Temperature Probe Features:
- Type-K thermocouple with standard shrouded banana jack
- Convenient one piece construction
- Compatible with DMMs with temperature measurement functions
- Measurement range:-40 to 260ºC
- One year warranty
Fluke 87V Specifications :
| Specifications | ||
| Voltage DC | Maximum Voltage | 1000V |
| Accuracy | ±(0.05%+1) | |
| Maximum Resolution | 10 µV | |
| Voltage AC | Maximum Voltage | 1000V |
| Accuracy | ±(0.7%+2) True RMS | |
| AC Bandwidth | 20kHz with low pass filter; 3db @ 1kHz | |
| Maximum Resolution | 0.1 mV | |
| Current DC | Maximum Amps | 10A (20 A for 30 seconds maximum) |
| Amps Accuracy | ±(0.2%+2) | |
| Maximum Resolution | 0.01 µA | |
| Current AC | Maximum Amps | 10A (20 A for 30 seconds maximum) |
| Amps Accuracy | ±(1.0%+2) True RMS | |
| Maximum Resolution | 0.1 µA | |
| Resistance | Maximum Resistance | 50 MΩ |
| Accuracy | ±(0.2%+1) | |
| Maximum Resolution | 0.1Ω | |
| Capacitance | Maximum Capacitance | 9,999 µF |
| Accuracy | ±(1%+2) | |
| Maximum Resolution | 0.01 nF | |
| Frequency | Maximum Frequency | 200 kHz |
| Accuracy | ±(0.005%+1) | |
| Maximum Resolution | 0.01 Hz | |
| Duty Cycle | Maximum Duty Cycle | 99.9% |
| Accuracy | ±(0.2% per khz +0.1%) | |
| Maximum Resolution | 0.1% | |
| Temperature Measurement | -200.0°C - 1090°C -328.0°F - 1994.0°F excluding probe |
|
| 80 BK Temperature Probe | -40.0°C - 260°C -40.0°F - 500°F, 2.2°C or 2% whichever is greater |
|
| Conductance | Maximum Conductance | 60.00 nS |
| Accuracy | ±(1.0%+10) | |
| Maximum Resolution | 0.01 nS | |
| Diode | Range | 3 V |
| Resolution | 1 mV | |
| Accuracy | ± (2 % + 1) | |
| Duty Cycle Range | Accuracy | Within ± (0.2% per kHz + 0.1 %) |
| Environmental Specifications | |
| Operating Temperature | -20°C to +55°C |
| Storage Temperature | -40°C to +60°C |
| Humidity (Without Condensation) | 0% - 90% (0°C - 35°C) 0% - 70% (35°C - 55°C) |
| Operating Altitude | 2000 m |
| Safety Specifications | |
| Overvoltage category | EN 61010-1 to 1000 V CAT III, 600V CAT IV |
| Agency Approvals | UL, CSA, TÜV, VDE listed |
| Mechanical and General Specifications | ||
| Size | 201 x 98 x 52 mm (with holster) | |
| Weight | 355 g 624 g - with holster |
|
| Display | Digital | 6000 counts updates 4/sec. 19,999 counts in high-resolution mode |
| Analog | 32 segments, updates 40/sec. | |
| Frequency | 19,999 counts, updates 3/sec at > 10 Hz | |
| Warranty | Lifetime | |
| Battery Life | Alkaline | ~400 hours typical, without backlight |
| Shock | 1 Meter drop per IEC 61010-1:2001 | |
| Vibration | Per MIL-PRF-28800 for a Class 2 instrument | |
Do you have a Industrial Electrician Combo Kit that needs to be calibrated?