Cart : (empty)

Fluke CNX-3000-HVAC - HVAC System

HVAC System

Fluke

Rated 0 / 5 (0 reviews)

Category : Electrical Testers

by quote only add to cart

Documents:
Datasheet

Overview
Features
Specifications
Calibration

The CNX 3000 HVAC System is part of the Fluke team of wireless troubleshooting tools.

Connect the CNX a3000 AC Wireless Current Clamp Module to your test point, and view the results up to 20 meters away on the CNX Wireless Multimeter. Plus, you can connect the CNX t3000 K-type wireless temperature module and view remote temperature measurements. You’ll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems. Or use as a stand-alone measurement tool or combine with other CNX modules as a system for multiple measurements. From short distances, you can even view readings from modules through closed electrical panels. Plus no more writing down data as the CNX remote modules captures up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. CNX wireless test tools also offer increased safety by letting you view readings in a separate location from the test point. Now you can take readings on moving machinery, with only the measurement module in harm’s way.

 

The CNX 3000 HVAC System provides measurement of all common electrical and temperature parameters.

The CNX 3000 Wireless Multimeter offers:

  • True-RMS AC and DC voltage measurements to 1000V
  • True-RMS AC and DC current with 0.01 mA resolution
  • Continuity, resistance, diode test, capacitance and frequency measurements
  • MIN/MAX Recording
  • CAT III 1000 V; CAT IV 600 V; IP54

The CNX t3000 K-Type Wireless Temperature Module offers:

  • Temperature measurements from -200 °C to 1372 °C
  • ± 0.5% accuracy
  • Memory recording up to 65,000 readings
  • Backlit LCD display; IP42 with thermocouple attached

The CNX a3000 AC Wireless Current Clamp Module provides:

  • True-RMA AC current measurements to 400 A
  • 2% accuracy to 100Hz, 2-1/2% accuracy to 500Hz
  • Memory recording up to 65,000 readings
  • iFlex current probe allows you to get into tight, awkward spaces
  • Backlit LCD display
  • CAT III 600 V; IP42

The CNX wireless system can track up to 10 measurement modules simultaneously, with results sent to a PC for detailed analysis.

 

CNX 3000 Wireless Multimeter

For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]). 

Detailed Specifications
AC voltage
Range ¹ Resolution Accuracy ² ³
45 Hz to 500 Hz 500 Hz to 1 kHz
600.0 mV 0.1 mV 1.0 % + 3 2.0 % + 3
6.000 V 0.001 V
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V
¹ All AC voltage ranges are specified from 1 % of range to 100 % of range. 
² Crest factor of ≤ 3 at full scale p to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V. 
³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3.

 

DC Voltage, Continuity, Resistance, Diode Test and Capacitance
Function Range Resolution Accuracy
mV 600.0 mV 0.1 mV 0.09 % + 2
V 6.000 V 0.001 V 0.09 % + 2
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V 0.15 % + 2
600 Ω 1 Ω Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
600.0 Ω 0.1 Ω 0.5 % + 2
6.000 kΩ 0.001 kΩ 0.5 % + 1
60.00 kΩ 0.01 kΩ
60.00 kΩ 0.1 kΩ
600.0 kΩ 0.001 MΩ
50.00 MΩ 0.01 MΩ 1.5 % + 3
Diode test 2.000 V 0.001 V 1 % + 2
µF 1000 nF 1 nF 1.2 % + 2
10.00 μF 0.01 μF
100.0 μF 0.1 μF
9999 μF¹ 1 μF 10 % typical
¹ In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.

 

AC and DC Current
Function Range¹ Resolution Accuracy
mA AC 
(45 Hz to 1 kHz)
60.00 mA 0.01 mA 1.5 % + 3
400.0 mA ³ 0.1 mA
mA DC ² 60.00 mA 0.01 mA 0.5 % + 3
400.0 mA 0.1 mA
¹ All AC current ranges are specified from 5 % of range to 100 % of range. 
² Input burden voltage (typical): 400 mA input 2 mV/mA. 
³ 400.0 mA accuracy specified up to 600 mA overload.

 

Frequency
Range Resolution Accuracy ¹
99.99 Hz 0.01 Hz 0.1 % + 1
999.9 Hz 0.1 Hz
9.999 kHz 0.001 kHz
99.99 kHz 0.01 kHz
¹ Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.

 

Input Characteristics
Function Overload 
Protection
Input Impedance 
(nominal)
Common Mode Rejection Ratio (1 kΩ unbalance) Normal Mode Rejection
1100 V RMS > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
1100 V RMS > 10 MΩ < 100 pF > 60 dB, DC to 60 Hz  
1100 V RMS > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
Open circuit test voltage Full scale Typical short circuit current
To 6 MΩ 50 MΩ
1100 V RMS < 2.7 V DC < 0.7 V DC < 0.9 V DC < 350 mA
1100 V RMS < 2.7 V DC 2.000 V DC < 1.1 mA

 

Function Overload Protection Overload
mA Fused, 44/100 A, 1000 V FAST Fuse 600 mA overload for 2 minutes maximum, 10 minutes rest minimum

 

MIN/MAX Recording
Function Accuracy
DC functions The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration.
AC functions The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration.

 

General Specifications
Maximum voltage between any terminal and earth ground 1000 V DC or AC RMS
Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD) Update rate: 4/sec 
Volts, amps, ohms: 6000 counts
Frequency: 10,000 counts 
Capacitance: 1,000 counts
Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
Battery life 300 hours minimum
Temperature Operating: -10 °C to 50 °C
Storage: -40 °C to 60 °C
Relative humidity 0 % to 90 % (0 °C to 35 °C)
0 % to 75 % (35 °C to 40 °C)
0 % to 45 % (40 °C to 50 °C)
Altitude Operating: 2,000 m 
Storage: 12,000 m
Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Wireless frequency 2.4 GHz ISM Band 20 meter range
Size (H x W x L) 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
Weight 340 g (12 oz)
Safety standards US ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL:UL 61010-1: 3rd edition
CE European: IEC/EN 61010-1:2010
Electromagnetic compatibility 
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006.
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) rating IP54

Accuracy is specified as ± ([% of reading] + [number of least significant digits]). All ranges are autoranging. Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.

 

Fluke CNX t3000 K-Type Wireless Temperature Module

 

Specifications

Range

K-Type: -200 °C to 1372 °C

Resolution

0.1 °C

Accuracy

± [0.5 % + 0.3 °C] counts

Input terminals

K-Type mini

LCD w/backlight

3 digits 

Log rate/interval

1 sec minimum/adjustable by PC

Battery type

2 AA, NEDA 15 A, IEC LR6

Battery life

400 hours

Memory

Record up to 65,000 readings

RF communications

2.4 GHZ ISM Band

RF communication range

20 Meters

Operating temperature

-10 °C to +50 °C

Storage temperature

-40 °C to +60 °C

Operating humidity

90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C

EMC

EN 61326-1:2006

Safety compliance

CAT 1 per IEC/EN 61010-1:2010
EN/IEC 61010-2-030:2010

Pollution degree

2

Temperature coefficient

0.01 % of reading +0.03 °C per °C

Certifications

CSA, FCC T68-FWCS IC:6627A-FWCS

Ingress Protection (IP) rating

IP42 with thermocouple attached

Size (HxWxD)

16.5 cm x 6.35 cm x 3.56 cm
(6.5 in x 2.5 in x 1.4 in)

Weight

.22 kg (8 oz)

Fluke CNX a3000 AC Wireless Current Clamp Module

 

Specifications

Range

400.0 A

Resolution

0.1 A

Accuracy

400.0 A:2 % ± 5 digits (10 Hz to 100 Hz)
2.5 % ± 5 digits (100 Hz to 500 Hz)

Inrush

Max displayed reading: 999.9A

Crest factor (50 Hz/60 Hz)

3.0 at 500 A, 2.5 at 600 A, 1.42 at 1000 A, add 2 %

Display

3-1/2 digits,  LCD w/backlight

Log rate/interval

1 sec minimum/adjustable by PC

Battery type

2 AA, NEDA 15 A, IEC LR6

Battery life

400 hours

Memory

Record up to 65,000 readings

RF communications

2.4 GHZ ISM Band

RF communication range

20 Meters

Operating temperature

-10 °C to +50 °C

Storage temperature

-40 °C to +60 °C

Operating humidity

90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C

EMC

EN 61326-1:2006

Safety compliance

EN/IEC 61010-1-30:2010 to 600 V Measurement Category (CAT) III
EN/IEC 61010-2-030:2010
EN/IEC 61010-2-032:2002

Pollution degree

2

Temperature coefficient

Add 0.1 X (specified accuracy)/ °C (<18 °C or >28 °C)

Safety rating

CAT III 600 V

Certifications

CSA, FCC T68-FWCS IC:6627A-FWCS

Ingress Protection (IP) rating

IP42

Size (HxWxD)

20.3 cm x 7.49 cm x 3.56 cm
(8 in x 2.95 in x 1.4 in)

Weight

.22 kg (8 oz)

Jaw opening

34 mm (1.33 in)


Do you have a HVAC System that needs to be calibrated?

We offer standard traceable calibration and ISO 17025 accredited calibration services.

Get your HVAC System calibrated today! Click Here!

 

There are currently no reviews for this product.

 

Review the Fluke CNX-3000-HVAC - HVAC System

HVAC System

Name :

Email :

Title :

Review: