Fluke I50S - AC Scope Current Probe, 50MHZ

AC Scope Current Probe, 50MHZ

Fluke

Rated 0 / 5 (0 reviews)

Category : Accessories

by quote only add to cart

Documents:
User's Manual

Overview
Features
Specifications
Calibration

Designed for use with bench oscilloscopes, the i50s Current Probe offers an ergonomic, robust and high performing solution for the measurement of DC and AC currents up to 50 MHz. With a permanent nominal current of 30 A RMS and a measuring capacity of 50 A for 10 s, as well as exceptional immunity to high common mode voltages (dv/dt = 5 kV/_s,) amplitude = 1,5 kV, error < 0,05 % of IPN), the i50s considerably widens the possibilities of accurate measurement of commutation currents.

 

  • Bandwidth DC up to 50 MHz
  • Nominal current 30 A
  • Max. current 50 A, < 10 s
  • Automatic zero adjustment and degauss functions
  • Overheating and head unlocked warning
  • Rise time < 7 ns
  • External magnetic field rejection rate AC and DC 60 dB
  • Rejection rate of fast dv/dt (5kV/_s) < 15 mA t

 

Electrical Characteristics
Nominal current (In) ± 30 A dc or A rms
Measuring range (duration <10 sec) I max ±50 A pk
Output sensitivity low range 1 V/A (1 MΩ)
High range 100 mV/A (1 MΩ)
Overall accuracy (dc to 100 Hz at 25 °C ± 0.5 % at In typical
± 1.5 % at I max
Gain variation (max) ± 0.04 % of rdg/ °C
Step response in Data Sheet
Frequency response in Data Sheet
Insertion impedance (ZI) in Data Sheet
< 0.1 Ω up to 10 MHz
< 0.4 Ω 10 MHz to 50 MHz
External magnetic field rejection rate 60 dB (ac and dc)
Rejection rate of fast dV/dt at 5 kV/ μs < 15 m At (during dV/dt)
Output noise level (measured with a filter at 25 MHz) 1 m At rms typical
Output noise level (measured with a filter at 25 MHz) 9 mA tpp
Dynamic Characteristics
Bandwidth DC to 50MHz(-3dB)
Frequency derating (see Figure 4) 10 A at 10MHz
Rise time, (10 % to 90 %) < 7ns
Delay time < 25 ns
Overshoot < 5 % of reading
General Characteristics
Aperture dimensions 5 x 5 mm (0.2 in x 0.2 in)
Max primary conductor temp 60 ° C (140 °F)
Dielectric withstand 1350 Vrms / 50 Hz / 1 min
Working voltage 300 Vrms or DC (CAT I)
150 Vrms or DC (CAT II)
Operating temperature °C to + 40 °C (32 °F to 104 °F)
Storage temperature -10 °C to + 60 °C (14 °F to 140 °F)
Maximum altitude 2000 m (6600 ft)
Maximum relative humidity 80 % , 31 °C (87 °F)
Environment Indoor use only
Power supply ± 12 V ± 0.5 V
Current consumptions at nominal 30 A 550 mA
Current consumption during demagnetization 1.3 A (for 6 sec) Probe
Output cable length 2 m (6.6 ft)

Do you have a AC Scope Current Probe, 50MHZ that needs to be calibrated?

We offer standard traceable calibration and ISO 17025 accredited calibration services.

Get your AC Scope Current Probe, 50MHZ calibrated today! Click Here!

 

There are currently no reviews for this product.

 

Review the Fluke I50S - AC Scope Current Probe, 50MHZ

AC Scope Current Probe, 50MHZ

Name :

Email :

Title :

Review: