Fluke 789/T3000-FC - ProcessMeterTM and Temperature Kit
Double your power
The Fluke 789 ProcessMeter is the ultimate troubleshooting tool for electricians and instrumentation professionals, combining the functionality of a loop calibrator with the power of a digital multimeter. By equipping the 789 with a temperature measurement module and the wireless data logging capabilities of Fluke Connect™ with ShareLive™ video call, process technicians can now do a lot more while carrying a lot less. And with its built-in, selectable 250 ohm HART® resistor, it eliminates the need to carry a separate resistor with you.
Use the included FC Connector with the Fluke 789 and get the full benefits of the Fluke Connect™ app. Download it now and get started.
Fluke Connect is not available in all countries.
©2015 Fluke Corporation. All trademarks are the property of their respective owners. Smart phone, wireless service and data plan not included with purchase. First 5 GB of storage is free. Compatible with iPhone 4x and up running iOS 7 or higher; iPad (in an iPhone frame on iPad); Samsung Galaxy S4 running Android 4.3.x or higher and Samsung Galaxy S, Nexus 5, HTC One and One M8 running Android™ 4.4.x or higher. Apple and the Apple logo are trademarks of Apple Inc. registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Google Play is a trademark of Google Inc.
Fluke 789 Temperature Kit features:
- Unique new wireless measurement logging capability
- Temperature measurement from -200°C to 1372°C using the t3000 FC
- 24 V Loop power supply
- HART mode setting with loop power (adds 250 ohm resistor)
- 100% larger dual display
- 1200 ohm drive capability on mA source
- Enhanced backlight with two brightness settings
- 0% to 100% mA Span Check buttons to toggle between 4 and 20 mA
- Infrared I/O serial port compatible with
- FlukeView® Forms Software Version 2.1
- Externally accessible fuses for easy replacement
These 787 features are also included in the 789:
- DMM designed to meet 1000 volt IEC 1010 CAT III standards
- Precision 1000 V, 440 mA True-RMS digital multimeter
- Frequency measurement to 20 kHz
- Min/Max/Average/Hold/Relative modes
- Diode test and continuity beeper
- Simultaneous mA and % of scale readout
- 20 mA DC current source/loop calibrator/ simulator
- Manual Step (100%, 25%, Coarse, Fine) plus Auto Step and Auto Ramp
- Externally accessible battery for easy battery changes
Fluke Connect is not available in all countries.
©2015 Fluke Corporation. All trademarks are the property of their respective owners. Smart phone, wireless service and data plan not included with purchase. First 5 GB of storage is free. Compatible with iPhone 4x and up running iOS 7 or higher; iPad (in an iPhone frame on iPad); Samsung Galaxy S4 running Android 4.3.x or higher and Samsung Galaxy S, Nexus 5, HTC One and One M8 running Android™ 4.4.x or higher. Apple and the Apple logo are trademarks of Apple Inc. registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Google Play is a trademark of Google Inc.
Fluke 789 ProcessMeter™ with Fluke Connect™
| Specifications | ||
| Current measurement | Range | 0-1 A AC or DC |
| Resolution | 1 mA | |
| Accuracy | 0.2% + 2 LSD (DC) | |
| Range | 0-30 mA | |
| Resolution | 0.001 mA | |
| Accuracy | 0.05% + 2 lSD | |
| Current sourcing | Range | 0-20 mA or 4-20 mA |
| Resolution | 0.05% of span | |
| Drive capability | 24 V Compliance or 1200 Ω @ 20 mA | |
| Frequency | to 19.999 kHz, 0.005% + 1 LSD | |
| Continuity | Beeps for resistance < 100 Ω | |
| Voltage measurement | Range | 0-1000 V AC (true-rms) or DC |
| Resolution | 0.1 mV to 1.0 V | |
| Accuracy | 0.1% Rdg + 1 LSD (V DC) | |
| Resistance measurement | to 40 MΩ, 0.2% + 1 LSD | |
| Diode test | 2.0 V shoes diode voltage drop | |
| Display current and % of span | Yes | |
| Auto Step, Auto Ramp | Yes | |
| Environmental Specifications | ||
| Operating temperature | -20°C to 55°C | |
| Storage temperature | -40°C to 60°C | |
| Humidity (without condensation) | 95% up to 30°C 75% up to 40°C 45% up to 50°C 35% up to 55°C |
|
| Temperature coefficient | 0.05 x (specified accuracy) per °C (for temperatures < 18°C or > 28°C) | |
| Safety Specifications | ||
| Electrical safety | Designed in accordance with IEC 1010-1, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No 1010.1-92 | |
| Overvoltage category | IEC 1010-1 CAT III 1000 V IEC 1010-1 CAT IV 600 V |
|
| Maximum voltage | 1000 V RMS | |
| Mechanical and General Specifications | ||
| Size (H x W x L) | 50 x 100 x 203 mm (1.25 x 3.41 x 7.35 in) | |
| Weight | 610 g (1.6 lbs) | |
| Batteries | 4 AA alkaline batteries | |
| Warranty | 3 years | |
| Battery life | 140 hours typical (measurement), 10 hours typical (sourcing 20 mA) | |
| Shock and vibration | Random, 2 g, 5-500 Hz 1 meter drop test |
|
Fluke t3000 FC Wireless K-Type Temperature Module
| General Specifications | ||||
| Range K-Type | -200°C to 1372°C | |||
| Resolution | 0.1°C | |||
| Accuracy | ±[0.5% + 0.5°C] counts | |||
| Input terminals | K-type mini | |||
| LCD w/backlight | 3 ½ digits | |||
| Log rate/interval | 1 sec minimum/adjustable by PC | |||
| Battery type | 2 AA, NEDA 15 A, IEC LR6 | |||
| Battery life | 400 hours | |||
| Memory | Record up to 65,000 readings | |||
| RF communications | 2.4 GHZ ISM Band | |||
| RF communication range | Open air, unobstructed | Up to 20 m | ||
| Obstructed, sheetrock wall | Up to 6.5 m | |||
| Obstructed, concrete wall or steel electrical enclosure | Up to 3.5 m | |||
| Operating temperature | -10°C to +50°C | |||
| Storage temperature | -40°C to +60°C | |||
| Temperature coefficient | 0.01% of reading +0.03°C per °C | |||
| Temperature scale | ITS-90 | |||
| Operating humidity | 90% at 35°C, 75% at 40°C, 45% at 50°C | |||
| Altitude | Operating | 2,000 m | ||
| Storage | 12,000 m | |||
| EMC | EN 61326-1:2006 | |||
| Safety compliance | IEC 61010-1, CAT I, 3rd edition Pollution Degree 2 | |||
| Certifications | CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE | |||
| Ingress Protection (IP) rating | IP42 | |||
| Pollution Degree | 2 | |||
| Size (H x W x D) | 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in) | |||
| Weight | .22 kg (8 oz) | |||
| Not compatible with Fluke CNX test tools | ||||
Fluke Connect is not available in all countries.
©2015 Fluke Corporation. All trademarks are the property of their respective owners. Smart phone, wireless service and data plan not included with purchase. First 5 GB of storage is free. Compatible with iPhone 4x and up running iOS 7 or higher; iPad (in an iPhone frame on iPad); Samsung Galaxy S4 running Android 4.3.x or higher and Samsung Galaxy S, Nexus 5, HTC One and One M8 running Android™ 4.4.x or higher. Apple and the Apple logo are trademarks of Apple Inc. registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Google Play is a trademark of Google Inc.
Do you have a ProcessMeterTM and Temperature Kit that needs to be calibrated?
We offer standard traceable calibration and ISO 17025 accredited calibration services.
Get your ProcessMeterTM and Temperature Kit calibrated today! Click Here!
There are currently no reviews for this product.