AMPROBE 33XR-A - Digital Multimeter with Temperature
Overview
Features
Specifications
Calibration
Amprobe 33XR-A is a manual ranging digital multimeter with temperature and capacitance for field service technicians.
- Min/max, relative, peak and data hold
- Auto power off to save battery life
- Separate door for easy battery and fuse access
- Magne-Grip™ Holster with magnetic hanging strap
- Display: 3-3/4 digit LCD, 3999 counts with 41-segment analog bar graph
- Display update rate: 2/sec, nominal
- Analog bar graph
- Overrange indication
- Operating temperature: 0 °C to 45 °C at < 70 % R.H.
- Storage temperature: -20 °C to 60 °C,
- Input warning tone when test leads are in wrong jack
| FEATURE | 33XR-A |
| DC Voltage | 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V |
| AC Voltage | 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V |
| DC Current | 400.0 µA, 4.000 mA, 40.00 mA, 300.0 mA, 10 A |
| AC Current | 400.0 µA, 4.000 mA, 40.00 mA, 300.0 mA, 10 A |
| Resistance | 400.0 O, 40.00 kO, 4.000 MO |
| Continuity | • |
| Diode | • |
| VolTect™ Non-Contact Voltage Detection | - |
| Capacitance | 4.000 µF, 40.00 µF, 400.0 µF, 4000 µF |
| Frequency | 4.000 kHz, 40.00 kHz, 400.0 kHz, 1 MHz |
| Temperature | 1832 °F (1000 °C) |
| Duty cycle | – |
| Logic test | – |
| Inductance | – |
| dBm | – |
| Specifications | |
| DC Voltage ranges: | 400 mV, 4 V, 40 V, 400 V, 1000 V |
| DC Voltage accuracy: | all ranges: ± (0.7 % rdg + 1 dgt) |
| DC Voltage resolution: | 100 µV |
| DC Voltage input impedance: | 10 MO |
| AC Voltage (45 Hz to 500 Hz) ranges: | 400 mV, 4 V, 40 V, 400 V, 750 V |
| AC Voltage (45 Hz to 500 Hz) accuracy: | 4 V Range, 200 Hz to 500 Hz: ± (2.0 % rdg + 4 dgts) |
| AC Voltage (45 Hz to 500 Hz) accuracy: | All other ranges: ± (1.5 % rdg + 4 dgts) |
| AC Voltage (45 Hz to 500 Hz) resolution: | 100 µV |
| AC Voltage (45 Hz to 500 Hz) input impedance: | 10 MO |
| DC Current ranges: | 400 µA, 4 mA, 40 mA, 300 mA, 10 A |
| DC Current accuracy: | 400 µA to 300 mA ranges: ± (1.0 % rdg + 1 dgt) |
| DC Current accuracy: | 10 A range: ± (2.0 % rdg + 3 dgts) |
| DC Current resolution: | 0.1 µA |
| DC Current voltage burden: | 400 µA range: 1 mV/µA, 4 mA range: 100 mV/1 mA, 40 mA range: 12 mV/1 mA, |
| DC Current voltage burden: | 300 mA range: 4 mV/1 mA, 10 A range: 100 mV/1 A |
| AC Current (45 Hz to 500 Hz) ranges: | 400 µA, 4 mA, 40 mA, 300 mA, 10 A |
| AC Current (45 Hz to 500 Hz) accuracy: | 400 µA to 300 mA ranges: ± (1.5 % rdg + 4 dgts) |
| AC Current (45 Hz to 500 Hz) accuracy: | 10 A range: ± (2.5 % rdg + 4 dgts) |
| AC Current resolution: | 0.1 µA |
| AC Current voltage burden: | See DC Current |
| Resistance ranges: | 400 O 40 kO 4 MO |
| Resistance accuracy: | 400 Oand 40 kO ranges: ± (1.0 % rdg + 4 dgts) |
| Resistance accuracy: | 4 MO range: ± (1.2 % rdg + 4 dgts) |
| Resistance resolution: | 100 mO |
Do you have a Digital Multimeter with Temperature that needs to be calibrated?
We offer standard traceable calibration and ISO 17025 accredited calibration services.
Get your Digital Multimeter with Temperature calibrated today! Click Here!
There are currently no reviews for this product.
