AMPROBE ACD-10-TRMS-PLUS - 600A Clamp Multimeter
Overview
Features
Specifications
Calibration
Amprobe ACD-10 TRMS-PLUS clamp meter takes AC/DC measurement with true-rms accuracy and offers capacitance and frequency. It also offers thinner jaws over standard clamp meters allowing access to tight areas and still accommodates conductors up to 25 mm.
- AC & DC Voltage to 600V
- AC Current to 600A
- Thin jaws, only 10mm (0.4) thick
- Resistance to 40MΩ
- Continuity buzzer
- Capacitance to 3000 uF
- Frequency measurement
- In rush current
- Hold & maximum reading functions
- Accommodates conductors up to 26mm (1.02) in diameter
- Auto ranging
- Auto power off
- Rubber over-molded case
- Overload protected
- True-rms measurement
- Included accessories: test leads, battery installed, soft carrying pouch, and users manual
| FEATURE | ACD-10 PLUS | ACD-10 TRMS-PLUS |
| True-rms | - | • |
| AC Voltage | 4.000 V, 40.00 V, 400.0 V, 600 V | |
| DC Voltage | 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 600 V | |
| AC Current | 40.00 A, 400.0 A, 600 A | |
| Resistance | 400.0 Ω, 4.000 kΩ, 40.00 kΩ, 400.0 kΩ, 4.000 MΩ, 40.00 MΩ | |
| Capacitance | 500.0 nF, 5.000 μF, 50.00 μF, 500.0 μF, 3000 μF | |
| Frequency | 40 Hz → 400 Hz with Jaw, 10 Hz → 100 kHz with test leads | |
| Temperature | - | - |
| Dual displays | - | - |
| Micro Amps | - | - |
| Accommodates conductors | up to 1.0†(25 mm) in diameter | |
| Specifications | |
| Display: | 3-3/4 digits 4000 counts LCD display |
| Update rate: | 3 per second nominal |
| Polarity: | Automatic |
| Operating temperature: | °C to 40 °C; < 80% RH for temperature up to 31 °C decreasing linearly to 50% RH at 40 °C |
| Altitude: | Operating below 2000m; Indoor use |
| Storage temperature: | -20 °C to 60 °C, < 80% RH (with battery removed) |
| Temperature coefficient: | nominal 0.15 x (specified accuracy)/°C @(0 °C ~ 18 °C or 28 °C ~ 40 °C) |
| Low battery: | Below approx. 2.4V |
| Power supply: | 3V coin battery IEC-CR2032 |
| Power consumption: | 2.8 mA typical except that 3.3 mA typical for ACA function |
| APO timing: | Idle for 30 minutes |
| APO consumption: | 5 µA typical |
| Jaw opening & conductor diameter: | max 26 mm |
| Special features: | 30ms Max Hold; Data Hold; Relative Zero mode |