AMPROBE ACD-10-PLUS - 600A Clamp Multimeter
Overview
Features
Specifications
Calibration
The Amprobe ACD-10 PLUS clamp multimeter has thinner jaws than standard digital clamp multimeters (only 0.4"/10mm thick) allowing access to tight measurement areas and still handles conductors up to 1.0 (25mm).
It combines the convenience and flexibility of an AC/DC current clamp meter with the most frequently used digital multimeter functions, including ac/dc current and voltage, capacitance, and frequency.
- Measures AC and DC voltage to 600V and AC current to 600A to handle residential/commercial and small industrial applications
- Thin jaws, only 10mm (0.4") thick make it easier to maneuver between tightly packed conductors
- Measures frequency, resistance, and capacitance
- Features continuity beeper to quickly find opens and shorts
- Accommodates conductors up to 1.0" (25mm) in diameter
- Auto ranging saves time by instantly selecting correct range
- Auto power off to conserve battery life
- Rubber over-molded case absorbs shock
- Includes test leads, battery (installed), soft carrying pouch, and users manual
| FEATURE | ACD-10 PLUS | ACD-10 TRMS-PLUS |
| True-rms | • | • |
| AC Voltage | 4.000 V, 40.00 V, 400.0 V, 600 V | |
| DC Voltage | 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 600 V | |
| AC Current | 40.00 A, 400.0 A, 600 A | |
| Resistance | 400.0 µΩ, 4.000 Ω, 40.00 Ω, 400.0 Ω, 4.000 MΩ, 40.00 MΩ | |
| Capacitance | 500.0 nF, 5.000 F, 50.00 CF, 500.0 µF, 3000 µF | |
| Frequency | 40 Hz → 400 Hz with Jaw, 10 Hz → 100 kHz with test leads | |
| Temperature | - | - |
| Dual displays | - | - |
| Micro Amps | - | - |
| Accommodates conductors | up to 1.0''(25 mm) in diameter | |
| Specifications | |
| Display: | 3-3/4 digits 4000 counts LCD display |
| Update rate: | 3 per second nominal |
| Polarity: | Automatic |
| Operating temperature: | °C to 40 °C; < 80% RH for temperature up to 31 °C decreasing linearly to 50% RH at 40 °C |
| Altitude: | Operating below 2000m; Indoor use |
| Storage temperature: | -20 °C to 60 °C, < 80% RH (with battery removed) |
| Temperature coefficient: | nominal 0.15 x (specified accuracy)/°C @(0 °C ~ 18 °C or 28 °C ~ 40 °C) |
| Low battery: | Below approx. 2.4V |
| Power supply: | 3V coin battery IEC-CR2032 |
| Power consumption: | 2.8 mA typical except that 3.3 mA typical for ACA function |
| APO timing: | Idle for 30 minutes |
| APO consumption: | 5 µA typical |
| Jaw opening & conductor diameter: | max 26 mm |
| Special features: | 30ms Max Hold; Data Hold; Relative Zero mode |
Do you have a 600A Clamp Multimeter that needs to be calibrated?
We offer standard traceable calibration and ISO 17025 accredited calibration services.
Get your 600A Clamp Multimeter calibrated today! Click Here!
There are currently no reviews for this product.