Your Cart
(empty)
0
Tradeport Electronics
measurement is our business
Cart : (empty)

Fluke 789/773 BU - 789 and 773 Bundle Package

789 and 773 Bundle Package

Fluke

Rated 0 / 5 (0 reviews)

Category : Multimeters

by quote only add to cart

Documents:
789 Datasheet

Overview
Features
Specifications
Calibration

Fluke 789 ProcessMeter

Now compatible with Fluke Connect™ App

The Fluke 789 ProcessMeter is the ultimate troubleshooting tool for electricians and instrumentation professionals, combining the functionality of a loop calibrator with the power of a digital multimeter. By equipping the 789 with a temperature measurement module and the wireless data logging capabilities of Fluke Connect™ with ShareLive™ video call (sold separately), process technicians can now do a lot more while carrying a lot less. And with its built-in, selectable 250 ohm HART® resistor, it eliminates the need to carry a separate resistor with you.

 

Fluke 773 Milliamp Process Clamp Meter

Need more hours in your day?

Save time by NOT breaking the loop on 4-20 mA signal measurements.

Are you spending time:

  • Taking mA measurements by removing a wire and breaking the loop
  • Calling the control room to isolate a loop
  • Testing analog input/output on a console
  • Troubleshooting devices with mA inputs and outputs
  • Repairing intermittent or erratic 4-20 mA loops
  • Going back to the shop to get extra tools

If you need more time in your busy day take a good look at the Fluke 773 mA Clamp Meters. It’s designed to save you time, and money, by eliminating time wasting activities. Now you can troubleshoot and repair 4-20 mA loops without breaking the loop or bringing down the system.

Here are some specific ways the Fluke 773 Clamp Meters will help you:

Milliamp Clamp Features

Measure mA signals for PLC and control system analog I/O without breaking the loop

  • Measures low level dc current
  • Correlate process indication with real physical value

Measure output signals from transmitters without breaking the loop

  • Maintain and troubleshoot process and automation equipment without breaking the loop
  • No disruption to the process

Detachable clamp with extension cable

  • Measurements in tight locations
  • Enables measurements in difficult situations

Measurement Spotlight

  • Illuminates hard to see wires in dark enclosures
  • Measurement process is easier and quicker

Measure up to 99.9 mA range non-contact

  • Wide range of measurements
  • Measures 10 to 50 mA signals in older control systems

Automatic power off

  • After 15 minutes and 2 minute automatic off for backlight and spotlight
  • Saves battery life

 

Features of the Fluke 789:

  • 24 V Loop power supply
  • Very large dual display
  • Enhanced backlight with 2 brightness settings
  • 1200 ohm drive capability on mA source
  • HART mode setting with loop power and a built-in 250 ohm resistor
  • 0% and 100% buttons to toggle between 4 and 20 mA sourcing for a quick span check
  • Externally accessible fuses for easy replacement
  • Infrared-port to process data in FlukeView Forms (V2.1) software

Fluke 789 features that are also included in the Fluke 787:

  • Precision 1000 V, 440 mA True-RMS digital multimeter
  • 0.1% dc voltage accuracy
  • 0.05% dc current accuracy
  • Frequency measurement to 20 kHz
  • Min/Max/Average/Hold/Relative modes
  • Diode Test and Continuity Beeper
  • Simultaneous mA and % of scale readout
  • 20 mA DC current source / loop calibrator / simulator
  • Manual Step (100%, 25%, Coarse, Fine) plus Auto Step and Auto Ramp
  • Externally accessible battery for easy battery changes

Safety conformance

Meets 1000 Volt EN61010-1 CAT III standards and 600 Volt EN61010-1 CAT IV standards.

The 773 mA Clamp Meter features:

  • Best in class 0.2% accuracy
  • 0.01 mA resolution and sensitivity
  • Measure 4 to 20 mA signals without “breaking the loop”
  • Measure mA signals for PLC and control system analog I/O
  • Dual backlit display with both mA measurement and percent of 4 to 20 mA span
  • Measurement Spotlight illuminates hard to see wires in dark enclosures
  • Detachable clamp with extension cable for measurements in tight locations
  • Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
  • Automatically change the 4 to 20 mA output for remote testing
  • Power saving features, auto-off, backlight timeout extend battery life
  • Hold function captures and displays changing measurements
  • Measure 4 to 20 mA signals with in-circuit measurement
  • Simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters
  • Source 4 to 20 mA signals for testing control system I/O or I/Ps
  • mA output linear ramp or 25% step output
  • Automatically change the 4 to 20 mA output for remote testing
  • DC voltage measurement to verify 24V power supplies or voltage I/O signals
  • Source DC voltage to test input devices that accept a 1-5V or 0 to 10V signals
  • Scaled mA output provides a continuous mA signal that corresponds to the 4 to 20 mA signal measured by the mA clamp
  • Enables milliamp signal logging to a separate logging device without breaking the loop
  • Output mA signal enables a logging DMM or other device to record the 4- to 20 mA signal without breaking the loop
  • mA in/out: simultaneously measure the mA signal with the clamp and source a mA signal
  • Apply a mA input signal to a device and measure its’ 4-20 mA output on devices such as valves or mA isolators
  • Voltage output linear ramp or 25% step output
  • Automatically change the voltage output for remote testing
Fluke 789 ProcessMeter Specifications
Current measurement Range 0-1 A AC or DC
Resolution 1 mA
Accuracy 0.2% + 2 LSD (DC)
Range 0-30 mA
Resolution 0.001 mA
Accuracy 0.05% + 2 lSD
Current sourcing Range 0-20 mA or 4-20 mA
Resolution 0.05% of span
Drive capability 24 V Compliance or 1200 Ω @ 20 mA
Frequency to 19.999 kHz, 0.005% + 1 LSD
Continuity Beeps for resistance < 100 Ω
Voltage measurement Range 0-1000 V AC (true-rms) or DC
Resolution 0.1 mV to 1.0 V
Accuracy 0.1% Rdg + 1 LSD (VDC)
Resistance measurement to 40 MΩ, 0.2% + 1 LSD
Diode test 2.0 V shoes diode voltage drop
Display current and % of span Yes
Auto Step, Auto Ramp Yes
Environmental Specifications
Operating temperature -20°C to 55°C
Storage temperature -40°C to 60°C
Humidity (without condensation) 95% up to 30°C 
75% up to 40°C 
45% up to 50°C 
35% up to 55°C
Temperature coefficient 0.05 x (specified accuracy) per °C (for temperatures < 18°C or > 28°C)
Safety Specifications
Electrical safety Designed in accordance with IEC 1010-1, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No 1010.1-92
Overvoltage category IEC 1010-1 CAT III 1000 V 
IEC 1010-1 CAT IV 600 V
Maximum voltage 1000 V RMS
Mechanical and General Specifications
Size (H x W x L) 50 x 100 x 203 mm (1.25 x 3.41 x 7.35 in)
Weight 610 g (1.6 lbs)
Batteries 4 AA alkaline batteries
Warranty 3 years
Battery life 140 hours typical (measurement), 10 hours typical (sourcing 20 mA)
Shock and vibration Random, 2 g, 5-500 Hz 
1 meter drop test

 

Fluke 773 Milliamp Process Clamp Meter Specifications
Diameter of measurable conductor 0.177" or 4.5 mm max
Operating temperature -10 to 50ºC
Storage temperature -25 to 60ºC
Operating humidity < 90% @ <30ºC, < 75% @ 30 to 55ºC
Operating altitude 0 to 2000 m
IP rating IP 40
Size 44 x 70 x 246 mm (2 7/8 x 5 ¾ x 11 5/8 in)
Weight 410 g, (14.4 oz)
Vibration Random 2 g, 5 to 500 Hz
Shock 1 meter drop test (except the jaw)
EMI/RFI Meets EN61326-1 
For current measurement w/ JAW, add 1mA to specification for EMC field strengths of 1V/m up to 3V/m.
Temperature coefficient 0.01% ºC 
(< 18ºC or > 28ºC)
Power, battery life (4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms
Warranty Three years for electronics 
One year for cable and clamp assembly
Functional Specifications
mA measurement 
(measured by clamp)
Resolution / range 0 to 20.99 mA
Accuracy 0.2% + 5 counts
Resolution / range 21.0mA to 100.0 mA
Accuracy 1% + 5 counts
mA measurement (measured in series with test jacks) Resolution / range 0 to 24.00 mA
Accuracy 0.2% + 2 counts
mA source (maximum mA drive: 24 mA into 1,000 ohms) Resolution / range 0 to 24.00 mA
Accuracy 0.2% + 2 counts
mA simulate (maximum voltage 50 V dc) Resolution / range 0 to 24.00 mA
Accuracy 0.2% + 2 counts
Voltage source (2 mA maximum drive current) Resolution / range 0 to 10.00 V DC
Accuracy 0.2% + 2 counts
Voltage measure Resolution / range 0 to 30.00 V DC
Accuracy 0.2% + 2 counts

Do you have a 789 and 773 Bundle Package that needs to be calibrated?

We offer standard traceable calibration and ISO 17025 accredited calibration services.

Get your 789 and 773 Bundle Package calibrated today! Click Here!

 

There are currently no reviews for this product.

 

Review the Fluke 789/773 BU - 789 and 773 Bundle Package

789 and 773 Bundle Package

Name :

Email :

Title :

Review: