Your Cart
(empty)
0
Tradeport Electronics
measurement is our business
Cart : (empty)

Graphtec America GS-4TSR - Input Terminal Adapter 4 Channel Thermistor

Input Terminal Adapter 4 Channel Thermistor

Graphtec America

Category : Accessories

by quote only Add to Cart

Documents:

Overview
Features
Information
Calibration

The compact GL100 datalogger input terminal adapter with 4 channel thermistor for industries requiring climate monitoring and control such as greenhouse, hydroponics, agriculture and botanical rooms gives managers real time environment and climate monitoring. Fine arts museums and galleries are also served for controlled environment settings where the GL100 excells!

Measurement Data Temperature, Logic/Pulse (instant and accumulated)
Measurement ch Temperature
4ch(1)
Logic/Pulse Count
4ch(1)
Input Method Scans using photo-MOS relay. All channels are non-isolated input.
Range of Temperature Measurement Supports two types of thermistors
Type A: -40.0º to 105.0ºC; GS103AT-4Ptime
Type B: -40.0º to 120.0ºC; GS-103JT-4Ptime
Temperature Measurement Accuracy Main Unit
-40 ≤TS <0ºC ± 0.7ºC
0 ≤TS ≤35ºC ± 0.2ºC
35 < TS ≤70ºC ± 0.4ºC
70 < TS ≤120ºC ± 1.0ºC
Thermistor
±0.4ºC (represented value)
GS-103AT-4P / GS103JT-4P
Logic / Pulse Input Input Voltage Range
0 to +24V (single line ground input)
Input Signal
Wireless pressure point(2), open corrector, voltage input
Input Voltage Threshold
Approximately +2.5V
Hysteresis
Approximately 0.5V (+2v to +2.5V)
Range of Pulse Measurement Instant count: Maximum 200C / sampling interval
Accumulated value: Maximum 65535C(3)
Temperature Unit of Denomination ºC / ºF (selectable)
Sampling Intervals 0.5 | 1 | 2 | 5 | 10 | 20 | 30 sec
1 | 2 | 5 | 10 | 20 | 30 | 60 min
Processor Functionality Luminance 0 to 999,999 klxh
UV Ray 0 to 999,999W/cm2  (2)
Sampling Intervals 0.5 | 1 | 2 | 5 | 10 | 20 | 30 sec
1 | 2 | 5 | 10 | 20 | 30 | 60 min
Extension Cable Approx 200mm
Operating Environment -10º to 50ºC, 80% RH and below (non-condensed)
External Dimensions 46mm x 66mm x 35.5mm (excludes protrusion)
Weight 83g (2.92 oz)

(1) Measurement type for each channel can be seperately selected.
(2) A contact point, b contact point, NO, NC.
(3) Clear accumulated value by QUIT key or when starting recording.


Do you have a Input Terminal Adapter 4 Channel Thermistor that needs to be calibrated?

We offer standard traceable calibration and ISO 17025 accredited calibration services.

Get your Input Terminal Adapter 4 Channel Thermistor calibrated today! Click Here!