Fluke 1743 - Power Quality Logger
Power quality logging is easy with a compact and rugged Fluke power meter
The Fluke 1743 Power Quality Logger is an everyday power meter for technicians who troubleshoot and analyze power quality issues. Capable of simultaneously logging up to 500 power parameters for up to 85 days and monitoring for events, this power logger helps uncover intermittent and hard-to-find power quality issues. The included PQ Log software quickly assesses the quality of power at the service entrance, substation, or at the load, according to the latest EN50160 standard.
Applications
- Energy and power quality assessment – Validate performance of facility improvements by quantifying energy consumption, power factor, and general power quality before and after improvements
- Quality of service compliance – Validate incoming power quality at the service entrance and assess the effects of neighboring disturbing loads
- Power quality studies – Assess baseline power quality to validate compatibility with critical systems before installation
- Load studies – Verify electrical system capacity before adding loads
- Disturbance analysis – Uncover root cause of equipment malfunction for mitigation and predictive maintenance
- Measure voltage with premium accuracy: IEC61000-4-30 compliant voltage accuracy (0.1%)
- Installs inside the cabinet: Compact, fully-insulated housing and accessories fit easily in tight spaces next to live power systems – powered from the measurement line, no external supply required.
- Quickly validate quality of power: Assess power quality according to EN50160 power quality standard with statistical overview
- Rugged and reliable: Designed for everyday field use with no moving parts and durable insulated case with two year warranty
- Plug and play: Setup in minutes with automatic current probe detection and powering
- Determines the root cause: Included PQ Log software quickly analyzes trends, creates statistical summaries, and generates detailed graphs and tables
- Monitors power for the long-term: Data can be downloaded during recording without interruption
Loggers for every application
The portable Fluke 1743 Power Quality Logger is designed for easy installation and use, anywhere in low- and medium-voltage applications.
IP65 water-proof monitor for logging the most common power parameters including V, A, W, VA, VAR, PF, energy, flicker, voltage events, and THD.
Features:
- Measurement of common power parameters: V, A, W, VA, VAR, PF, energy, flicker, voltage events, and THD
- Wide range current measurement accessories for direct measurement or via installed current transformers.
- Dust/water resistance: IP65 water proof
- LED Status display
- 3 seconds UPS ride-through
- Dimensions (H x W x D): 170 x 125 x 55 mm (6.9 x 5.1 x 2.2 in)
| General Data | ||
| Intrinsic error | Refers to the reference conditions and is guaranteed for two years | |
| Warranty | 2 years | |
| Recalibration interval | 2 years recommended | |
| Quality system | developed, designed, and manufactured according to DIN ISO 9001 | |
| Reference conditions | 23°C ±2 K; 74°F ±2 K , Vm = 230 V ±10%, 50 Hz ±0.1 Hz or 60 Hz ±0.1 Hz | |
| Phase sequence | L1, L2, L3 | |
| Interval length | 10 minutes | |
| Wye connection | (L1, L2, L3 to N) | |
| Power supply | 88 V ... 265 V AC | |
| Environment conditions | Working temp. range | -10°C to 55°C; 14°F to 131°F |
| Operating temp. range | 0°C to 35°C; 32°F to 95°F | |
| Storage temp. range | -20°C to 60°C; -4°F to 140°F | |
| Reference temp. range | 23°C ±2 K; 74°F ±2 K | |
| Relative humidity | Class C2 acc. IEC 60654-1 | |
| Housing | robust, fully insulated housing and accessories | |
| Protection type | IP65 as per EN 60529 | |
| Safety | IEC/EN 61010-1 600 V CAT III, 300 V CAT IV, pollution degree 2, double insulation | |
| Type test voltage | 5.2 kV rms, 50 Hz / 60 Hz, 5 s | |
| EMC | Emission | IEC/EN 61326-1, EN55022 |
| Immunity | IEC/EN 61326-1 | |
| Voltage and Current Measurement | ||
| Input voltage | Input range VI P-N | max 480 V AC |
| Input range VI P-P | max 830 V AC | |
| Max. overload voltage | 1.2 VI | |
| Input range selection | By job programming | |
| Connections | P-P or P-N, 1- or 3-phase | |
| Nominal voltage VN | ≤ 999 kV with PTs and ratio | |
| Input resistance | App. 820 kΩ per chan. Lx-N Single phase (L1 or A, L2 or B, L3 or C connected): app. 300 kΩ | |
| Intrinsic uncenrtainty | 0.1% of VI | |
| Voltage transformer | Ratio: < 999 kV / VI | |
| Ration selection | By job programming | |
| Current input with Flexi Set | Input ranges II L1 or A, L2 or B, L3 or C, N | 15 A / 150 A / 1500 A / 3000 A AC |
| Measuring range | 0.75 A … 3000 A AC | |
| Intrinsic uncertainty | < 2% of II | |
| Position influence | Max. ±2% of measured value – for distance conductor to meas. head > 30 mm | |
| Stray field influence | < ±2 A AC for Iext = 500 A AC and distance to measuring head > 200 mm | |
| Temperature coefficient | < 0.05% / K | |
| Current transformer | Ratio ≤ 999 kA / II | |
| Ratio selection | By job programming | |
| Connection | 3-phase, 3-phase +N, 2 phase L1 or A and L3 or C (2 W-meter-method) 7 pole connector | |
| Current input for clamp | Input ranges II L1 or A, L2 or B, L3 or C, N |
0.5 V nominal (for II) 1.4 Vpeak |
| Intrinsic uncertainty | < 0.3% of II | |
| Max. overload | 10 V AC | |
| Input resistance | App. 8.2 kΩ | |
| Current transformer | Ratio Ω 999 kA / II | |
| Power systems | Delta, 2-Element Delta, Wye, Single Phase, Split Single Phase | |
| Logger | ||
| Power supply | Functional Range | 88 V to 660 V absolute, 50 Hz / 60 Hz |
| 100 V to 350 V DC Internal fuse: 630 mA T | ||
| Power consumption | 5 Watts | |
| Ride through | 3 sec Capacitor | |
| Fuse | Power supply fuse can be replaced in service facility only. Supply can be connected in parallel to measuring inputs (up to 660 V) | |
| Display, indicators | LEDs for status and voltage levels | |
| Memory | Capacity 8 MB Flash-EPROM | |
| Intervals | A function > 12000 intervals for > 85 days with 10 min intervals | |
| P function > 30000 intervals for > 212 days with 10 min intervals | ||
| Events | > 13000 | |
| Memory model | linear, circular | |
| Interface | RS 232, 9600...115 000 Baud, automatic Baud rate selection, 3-wire communication | |
| Dimensions | 170 x 125 x 55 mm (69 x 51 x 22 in) | |
| Weight | approx. 2 kg | |
| Measurement | A/D converter | 16 bit, sample rate: 10.24 kHz |
| Anti-aliasing filter | FIR-Filter, fc = 4.9 kHz | |
| Frequency response | Uncertainty < 1% of Vm for 40 Hz to 2500 Hz | |
| Interval length | 1, 3, 5, 10, 30 s, 1, 5, 10, 15, 60 minutes | |
| Averaging time for Min/max values | ½, 1 mains period, 200 ms, 1, 3, 5 s | |
| Time base | Resolution: 10 ms (at 50 Hz), deviation: 2 s/day at 23°C; 74°F ±2 K | |
Do you have a Power Quality Logger that needs to be calibrated?
We offer standard traceable calibration and ISO 17025 accredited calibration services.
Get your Power Quality Logger calibrated today! Click Here!
There are currently no reviews for this product.