GW Instek LCR-816-RS232 - 2kHz High Precision LCR Meter (with RS-232 Interface)
Instek LCR-816: Test Frequency: 100Hz~2kHz, Continuously Variable Frequencies - 0.1% Measurement Accuracy - 100 Sets Memory for Save/Recall of Setup State - R/Q, C/D, C/R, L/Q Test Modes - Absolute Value, Delta Value, and Delta % Measurement Display - 240 x 128 dot Matrix LCD Display - Test Condition and Test Result Shown on the Screen Simultaneously - Option: RS-232C (Including LCR-Viewer Software)
- 100Hz to 2kHz, Continuously Variable Frequencies
- 0.1% Measurement Accuracy
- 100 Sets Memory for Save/Recall of Setup State
- R/Q, C/D, C/R, L/Q Test Modes
- Absolute Value, ΔValue, and Δ% Measurement Display
- 240 x 128 dot Matrix LCD Display
- Test Condition and Test Result shown on the screen Simultaneously
- Option: RS-232C Interface, Inculding LCR-View Software
Test Frequency
| 12Hz ~ 200kHz (504 steps) for LCR-821 12Hz ~ 100kHz(503 steps) for LCR-819/829 12Hz ~ 10kHz(489 steps) for LCR-817/827 100Hz ~2kHz (245 steps) for LCR-816/826 |
Basic Accuracy (*)
| 0.05% for basic accuracy for LCR-821/819/817 0.1% for basic accuracy for LCR-829/827/826/816 |
Test Speed
| 68ms for LCR-821/819/817/816, 34ms for LCR-829/827/826 |
Test Signal Levels
| 5mV ~ 1.275Vrms ( 5mV/step ) for LCR-821/819/829/817/827 0.1V ~ 1.275Vrms ( 5mV/step )for LCR-816/826 |
DC Bias
| Internal | 2V |
| External | 0 ~ 35V for LCR-821; 0 ~ 30V for LCR-819/829/817/827/816/826 |
Display Range (**)
| Resistance | R 0.00001Ω ~ 99999kΩ |
| Capacitance | C 0.00001pF ~ 99999uF |
| Inductance | L 0.00001mH ~ 99999H |
| Quality Factor | Q 0.0001 ~ 9999 |
| Dissipation Factor | D 0.0001 ~ 9999 |
| Impedance | |Z| 0.00001Ω ~ 99999kΩ for LCR-821 |
| Phase Angle (Degree) | θ -180.00° ~ 180.00° for LCR-821 |
Test Mode
| R/Q, C/D, C/R, L/Q, Z/θ, L/R for LCR-821 only |
Equivalent Circuit
| Parallel or series selectable |
Memory
| 100 memory blocks total |
Average
| 1 to 255 times |
Test Speed Mode
| SLOW, MEDIUM and FAST |
Display Mode
| Value, △, △% |
Display
| 240 x 128 dot matrix C.C.F.L back light LCD |
Interface
| Standard : RS-232C for LCR-821 Standard : Handler Interface for LCR-829/827/826 Optional : RS-232C Interface for LCR-819/817/816 (Including LCR-Viewer Software for RS-232C interface) |
Power Source
| Line Voltage Range | 100V - 240V, 47-63Hz/400Hz |
Dimensions & Weight
| 330(W) x 149(H) x 437(D)mm Approx. 5.5kg |
(*):Basic accuracy varies with the speed, frequency, AC signal level and impedance of the device under test.
(**):Display range refers to the range of measurement values that can be displayed on the screen. Please see the LCR-800 user manual for the effective measurement ranges.
Do you have a 2kHz High Precision LCR Meter (with RS-232 Interface) that needs to be calibrated?
We offer standard traceable calibration and ISO 17025 accredited calibration services.
Get your 2kHz High Precision LCR Meter (with RS-232 Interface) calibrated today! Click Here!
There are currently no reviews for this product.