Soken DAC-PSC-UA - Precision C & tanδ Meter
DAC-PSC-UA is a high precision measuring instrument having minimum resolution 0.0001% in tanδ. By selecting a standard capacitor, capacitance range from small to large and voltage range from low to ultra-high are available. The measuring range can be expanded further by using with an expanding CT (100:1, 200:1 or 1000:1).
DAC-PSC-UA can measure small dielectric losses of specimens at high voltage, and applicable to tests for high voltage cables, insulation materials and bushings, etc. The meter will provide great help to research and development of dielectrics and insulation materials.
Application
● High-Voltage Cable
● Capacitors
● Insulation Materials
- Precise measurement of Capacitance and tanδ.
- Wide measurement range:
- Capacitance 50pF - 10μF (Max 10000μF when with expanding CT 1000:1)
- Testing Voltage AC 10V - 600kV
- Minimum Resolution of tanδ: 1×10^-6(1ppm)
Measuring Ranges
| Applicable Standard capacitor: 50pF – 10000pF *1 |
Standard Capacitor (Option) | |
| 50pF | 100pF | |
| Testing Voltage *2*3 | 2kV – 600kV | 1kV – 300kV |
| Capacitance*4 | 50pF – 50nF | 100pF – 100nF |
| with CT-1 (100:1) | 5nF - 5μF | 10nF - 10μF |
| with CT-2 (200:1) | 10nF - 10μF | 20nF - 20μF |
| with CT-10 (1000:1) | 50nF - 50μF | 100nF - 100μF |
| 1000pF | 10000pF | |
| Testing Voltage *2*3 | 0.1kV – 30kV | 10V – 3000V |
| Capacitance*4 | 1000pF – 1μF | 0.01uF–10uF |
| with CT-1 (100:1) | 100nF - 100μF | 1uF - 1000uF |
| with CT-2 (200:1) | 200nF - 200μF | 2μF - 2000μF |
| with CT-10 (1000:1) | 1μF - 1000μF | 10μF - 10000μF |
| tanδ | 0 - 10%(3 ranges, 0-0.2%、0-2%, 0-10%) | |
*1: 3 types of standard capacitors from Cs 50pF – Cs 10000pF shall be registered on the meter. (Cs 20000pF range is available upon request)
*2: Testing Frequency: 50/60Hz
*3: Accuracy guaranteed starting voltage (when tanδ range 2%, 10%) = Max testing voltage / 100 (kV) Accuracy guaranteed starting voltage (when tanδ range 0.2%) = Max testing voltage / 10 (kV)
*4: Capacitance ranges are subject to be limited by measurable current capacity 8A.
Minimum Resolution
| Capacitance: | 0.01pF | 6 digits. |
| Tanδ: | 0.0001%(1ppm) | 4 digits |
Measurement Accuracy
| Capacitance: | ±(0.1%rdg+2digits) |
| Tanδ: | ±(0.003%+1%rdg+2digits) |
Environment
| Operating | 15 - 35°C |
| Storage | 0 - 40°C |
| Humidity | less than 80%, no dew. |
General
| Interface | USB (2.0/1.1, B type connector) and GP-IB |
| AC source | AC100V - 240V±10% 50/60Hz |
| Size and Weight | W430×H250×D450 (mm) approx. 25kg |
| Accessory | Cs Connecting Cable (3M) x1, Cx Connecting Cable (3M) x1, AC code x1, Grounding cable x1, Accessory bag x1, Sample software |
Do you have a Precision C & tanδ Meter that needs to be calibrated?
We offer standard traceable calibration and ISO 17025 accredited calibration services.
Get your Precision C & tanδ Meter calibrated today! Click Here!