| Measurement Accuracy |
| Voltage DC |
| 30.000 V |
0.02%+ 2 counts (upper display) |
| 30.000 V |
0.02%+ 2 counts (lower display) |
| 100.00 mV |
0.02%+ 2 counts |
| -10.00 mV to 75.00 mV |
0.025 % + 1 count (via TC connector) |
|
| Current DC |
| 24.000 mA |
0.02%+ 2 counts |
|
| Resistance |
| 0.0 to 400.0 Ω |
0.1Ω (4-wire), 0.15Ω (2- and 3-wire) |
| 401 to 1500 Ω |
0.5Ω (4-wire), 1Ω (2- and 3-wire) |
| 1500 to 3200 Ω |
1Ω (4-wire), 1.5Ω (2- and 3-wire) |
|
| Frequency |
| 2.0 to 1000.0 CPM |
0.05 % + 1 count |
| 1.0 to 1100.0 Hz |
0.05 % + 1 count |
| 1.00 to 10.00 kHz |
0.05 % + 1 count |
| Sensitivity |
1 V peak-to-peak-minimum |
|
| Pressure |
| Accuracy |
from 0.025% of range using any of 29 pressure modules. |
| |
(for detailed specifications refer to pressure modules in options and accessories) |
| |
Modules available for differential, gauge, vacuum, absolute, dual and high pressure. |
|
| Source Accuracy |
| Voltage DC |
| 100.00 mV |
0.02%+2 counts |
| 10.000 V |
0.02%+2 counts |
| -10.00 mV to 75.00 mV |
0.025 % + 1 count (via TC connector) |
|
| Current DC |
| 24.000 mA (Source) |
0.02%+ 2 counts |
| 24.000 mA (Simulate) |
0.02%+ 2 counts |
|
| Resistance |
| 15.0 to 400.0 Ω |
0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA) |
| 401 to 1500 Ω |
0.5 Ω(excitation current 0.05 to 0.8 mA) |
| 1500 to 3200 Ω |
1 Ω(excitation current 0.05 to 0.4 mA) |
|
| Frequency |
| 2.0 to 1000.0 CPM |
0.05% |
| 1.0 to 1100.0 Hz |
0.05% |
| 1.00 to 10.00 kHz |
0.25% |
| Waveform: |
5 V p-p squarewave, -0.1 V offset |
|
| RTDs and Thermocouples |
| Measure Accuracy: |
| NI-120 |
0.2 °C |
| PT-100 (385) |
0.33 °C |
| PT-100 (393) |
0.3 °C |
| PT-100 (JIS) |
0.3 °C |
| PT-200 (385) |
0.2 °C |
| PT-500 (385) |
0.3 °C |
| PT-1000 (385) |
0.2 °C |
| Resolution: |
0.1 °C |
| J: |
0.7 °C |
| K: |
0.8 °C |
| T: |
0.8 °C |
| E: |
0.7 °C |
| R: |
1.8 °C |
| S: |
1.5 °C |
| B: |
1.4 °C |
| L: |
0.7 °C |
| U: |
0.75 °C |
| N: |
0.9 °C |
| Resolution |
J, K, T, E, L, N, U: 0.1 °C, 0.1 °F B, R, S: 1 °C, 1 °F |
| XK |
0.6°C |
| BP |
1.2°C |
|
| Source Accuracy: |
| NI-120 |
0.2 °C |
| PT-100 (385) |
0.33 °C |
| PT-100 (393) |
0.3 °C |
| PT-100 (JIS) |
0.3 °C |
| PT-200 (385) |
0.2 °C |
| PT-500 (385) |
0.3 °C |
| PT-1000 (385) |
0.2 °C |
| Resolution: |
0.1 °C |
| Note: |
Accuracy stated for 4-wire measurement. |
| J: |
0.7 °C |
| K: |
0.8 °C |
| T: |
0.8 °C |
| E: |
0.7 °C |
| R: |
1.4 °C |
| S: |
1.5 °C |
| B: |
1.4 °C |
| L: |
0.7 °C |
| U: |
0.75 °C |
| N: |
0.9 °C |
| Resolution |
J, K, T, E, L, N, U: 0.1 °C, B, R, S: 1 °C |
| XK |
0.6°C |
| BP |
1.2°C |
|
| Specifications |
| Ramp Functions |
<
| Source functions: |
Voltage, current, resistance, frequency, temperature |
| Ramps |
|
|
|
|