Fluke 707 - Loop Calibrator with Nist Cal with Data

   Loop Calibrator with Nist Cal with Data

Fluke

Rated 0 / 5 (0 reviews)

Category : Process Tools

by quote only add to cart

Documents:

Overview
Features
Specifications
Calibration

The fastest, one-handed tool for loop checks.

The Fluke 707 loop calibrator is a high performance solution for calibration, repair and maintenance of current loops. The new "Quick Click" knob making it extremely fast and easy to use. It features:

  • One handed user interface with "Quick Click" detented knob
  • mA sourcing, simulation and measurement
  • 0.015% accuracy and 0.001 mA resolution
  • Simultaneous mA and % of span display
  • Selectable step or ramp outputs
  • 24 V Loop supply with mA measure, including 250Ω HART resistor
  • 0-28 VDC measurement to check Loop Voltage
  • Easy battery exchange without opening the case
  • Compact case with separate protective holster
  • Three year warranty

The fast, one-handed tool for loop checks. Just click to calibrate.

This feature-rich solution combines the best features push-button and knob-base loop calibrator and offers:

  • Large display and simple, quick-click interface for easy one-handed operation.
  • Simultaneous mA and % readout for quick, easy interpretation of readings.
  • mA accuracy of 0.015%, superior to other loop calibrators in this price range.
  • 1 µA resolution for mA source, simulate and measure.
  • Push button 25% steps for fast, easy linearity checks.
  • 0-100% “span check” for fast confirmation of zero and span.
  • Selectable slow ramp, fast ramp, and step ramp to provide smooth outputs for valve slewing and loop functional tests.
  • 24 volt internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM.
  • Measures V dc to 28 V.
  • Single 9V battery that is easily changed without braking calibration seal
  • 0 - 20 mA or 4 - 20 mA default start up modes.
  • Innovative output adjustment dial with 1 µA and 100 resolution.
  • HART ™ mode connects 250 Ω resistor in series with 24 V loop for compatibility with HART communicators.

Safety conformance:
CSA C22.2 No. 1010.1:1992

 

Specifications
Current measurement Range: 0 to 24 mA
Resolution: 0.001 mA
Accuracy: 0.015% Rdg + 2 LSD
Current sourcing Range: 0 to 20 mA or 4 to 20 mA
Accuracy: 0.015% Rdg + 2 LSD
Drive capability: 1200 Ω; 950 Ω at 20 mA in HART mode
Current simulation Range: 0 to 20 mA or 4 to 20 mA
Accuracy: 0.015% Rdg + 2 LSD
Ext. loop voltage requirement: 12-30 V
Loop power While measuring mA, 24 V
Voltage measurement Range: 0 to 28 V DC
Resolution: 1 mV
Accuracy: 0.015% Rdg + 2 LSD
Environmental Specifications
Operating temperature -10ºC to 55ºC
Storage temperature -30ºC to 60ºC
Humidity (without condensation) 0 to 90% (0ºC to 35ºC); 0 to 70% (35ºC to 55ºC)
Temperature coefficient -10ºC to 18ºC, 28ºC to 55ºC, ±.005% of range per ºC
Safety Specifications
Safety CSA C22.2 No. 1010.1:1992
EMC EN50082-1:1992 and EN55022:1994 Class B
Maximum voltage 30V
Mechanical & General Specifications
Size 152 x 70 x 41 mm
Weight 224 g (340 g including holster)
Batteries One 9V battery Alkaline
Warranty Three years
Shock & vibration Per MIL-T-28800 for a Class 2 Instrument
Display current and % of span Yes
Auto step, auto ramp Yes
Span check Yes

Do you have a Loop Calibrator with Nist Cal with Data that needs to be calibrated?

We offer standard traceable calibration and ISO 17025 accredited calibration services.

Get your Loop Calibrator with Nist Cal with Data calibrated today! Click Here!

 