GW Instek GDS-806C - 60MHz, 2-channel, Color LCD Display DSO
Overview
Features
Specifications
Calibration
Instek GDS-806C: Max. Current 3A For GPC Series, GPD-3303S, GPR-U/M/H Series, GPS Series, PPE-3323, PPS-3635G, PPT-1830G/3615G, PSS-3203, PST-3201, SPD-3606
This product has been discontinued. Our replacement recommendation is the GDS-1072B - GW Instek 70MHz Digital Storage Oscilloscope
- 60MHz Bandwidth With COLOR Display
- 125k Memory and 12 Division Horizontal Display
- 25GS/s Sampling Rate for Repetitive Waveforms
- Advanced Trigger : Pulse Width , TV Line, Event Delay and Time Delay
- Go/NoGo , Auto Setup Sequence and TTF Function
- Built-In Help Menu, Multi-Language and FREE PC Software
- Standard Interface: RS-232C
- Optional Interface: GPIB, Printer Port and USB 2.0
| Display System | Display Device | Color (320 x 240) | ||||||
| Display Contrast | Adjustable | |||||||
| Waveform Display Graticule | 8 x 10 divisions (8 x 12 when menu off) | |||||||
|
|
||||||||
| Vertical System | Bandwidth | 60MHz | ||||||
| Channels | 2 | |||||||
| Vertical Resolution | 8-bit | |||||||
| Vertical Sensitivity | 2mV/div ~ 5V/div | |||||||
| Vertical Accuracy | ±3% | |||||||
| Rise Time | <5.8ns | |||||||
| Input Coupling | AC , DC , Ground | |||||||
| Input Impedance | 1MΩ ± 2% , ~18pF | |||||||
| Polarity | Normal and Invert | |||||||
| Max. Voltage Between Signal & | 300V ( DC+AC peak ) , CATII | |||||||
| common at Input BNC | ||||||||
| Waveform Signal Process | CH1 + CH2 , CH1 - CH2 , FFT | |||||||
| Offset Range | 2mV/div~50mV/div : ± 0.5V; 100mV/div~500mV/div : 1V/div~5V/div : ±50V | |||||||
| BW Limit | 20MHz ( -3dB ) | |||||||
|
|
||||||||
| Horizontal System | Time Base Range | 1ns/div ~ 10s/div ( 1-2-5 increments ), Roll : 250ms/div ~ 10s/div | ||||||
| Time Base Mode | Main , Window , Window Zoom , Roll , X-Y | |||||||
| Time Base Accuracy | ± 0.01% | |||||||
| Delay Range | Pre-trigger : 20 div | |||||||
|
|
||||||||
| Signal Acquisition | Real-Time Sample Rate | 100MS/s maximum on each channel | ||||||
| System | Equivalent Sample Rate | 25GS/s E.T. maximum on each channel | ||||||
| Record Length | 125h/CH | |||||||
| Peak Detection | 10ns (500ns/div ~ 10s/div) | |||||||
| Acquisition Mode | Sample , Peak Detect , Average | |||||||
| Average | 2 , 4 , 8 , 16 , 32 , 64 , 128 , 256 | |||||||
|
|
||||||||
| Trigger | Trigger Source | CH1 , CH2 , Line , Ext | ||||||
| Mode | Auto Level , Auto , Normal , Single , TV , Time Delay , Event Delay , Edge , | |||||||
| Pulse Width , AC , DC , HF , LF , Noise Reject | ||||||||
| Coupling | AC , DC , HF , LF , Noise Reject | |||||||
| Sensitivity | DC ~ 25MHz : Approximate 0.5div or 5mV | |||||||
| 25MHz ~ 60MHz : Approximate 1.5div or 15mV | ||||||||
|
|
||||||||
| X - Y Mode | X-Axis Input / Y-Axis Input | Channel 1 / Channel 2 | ||||||
| Phase Shift | ± 3° at 100 kHz | |||||||
|
|
||||||||
| Cursor and | Auto Voltage Measurement | Vpp , Vamp , Vavg , Vrms , Vhi , Vlo , Vmax , Vmin | ||||||
| Measurement | Auto Time Measurement | Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width, | ||||||
| Duty Cycle | ||||||||
| Cursor Measurement | Voltage difference between cursors (∆V), Time difference between | |||||||
| cursors (∆T), Frequency difference between cursors (1/∆T) | ||||||||
|
|
||||||||
| Frequency Counter | Readout Resolution | 6 digits | ||||||
| Frequency Range | AC Coupled , 20Hz~rated bandwidth ; resolution: 10Hz | |||||||
| Signal Source | All available trigger source except the Pulse Width & Video Trigger mode | |||||||
|
|
||||||||
| Adjustable Probe | Frequency Rang | 1 kHz ~ 100 kHz 1KHz / STEP | ||||||
| Calibration Signal | Duty Cycle | 5% ~ 95% 5% / STEP | ||||||
Do you have a 60MHz, 2-channel, Color LCD Display DSO that needs to be calibrated?
We offer standard traceable calibration and ISO 17025 accredited calibration services.
Get your 60MHz, 2-channel, Color LCD Display DSO calibrated today! Click Here!
There are currently no reviews for this product.