GW Instek GCP-0275 - Current Probe
Overview
Features
Specifications
Calibration
Current Measurement Solutions
2 MHz / 5 MHz / 25 MHz AC/DC Current Probes
Observe current waveforms and understand circuit behaviour with AC/DC current probes available in 2 MHz, 5 MHz and 25 MHz bandwidth options. Choose the model that matches your measurement frequency, current range and oscilloscope requirements.
AC/DC Measurement 2 MHz 5 MHz 25 MHz
Features
- Easy-to-use and accurate AC/DC current measurements
- Low noise and DC drift
- Split-core probe head construction allows easy connection to conductors
- DC to 2 MHz, 750 A
- Applicable devices: GDS-3000/A Series, GDS-2000A/E Series, GDS-2000HD/HG Series, GDS-1000B Series, GDS-912/G Series, MDO-2000A/E Series, MPO-2000 Series, MSO-2000E Series
| Model | GCP-0275 | GCP-0550 | GCP-2525 |
|---|---|---|---|
| Bandwidth (-3 dB) | DC to 2 MHz | DC to 5 MHz | DC to 25 MHz |
| DC + Peak AC MAX. (non-continuous) | 750 A (*1) | 500 A (*2) | 250 A (*3) |
| Continuous Maximum Current (RMS) | 500 Arms | 350 Arms | 170 Arms |
| Minimum Current | 50 mA | 20 mA | 20 mA |
| Rise Time | 175 ns or less | 70 ns or less | 14 ns or less |
| Conversion Ratio |
2 mV/A (X 500)
20 mV/A (X 50)
|
5 mV/A (X 200)
50 mV/A (X 20)
|
10 mV/A (X 100)
100 mV/A (X 10)
|
| Accuracy |
2 mV/A : 1 % ± 1 mV
20 mV/A : 1 % ± 1 mV
|
5 mV/A : 1 % ± 1 mV
50 mV/A : 1 % ± 2 mV
|
10 mV/A : 1 % ± 1 mV
100 mV/A : 1 % ± 5 mV
|
| Current Range (DC + Peak AC) |
2 mV/A : 125 A to 750 A
20 mV/A : 50 mA to 150 A
|
5 mV/A : 50 A to 500 A
50 mV/A : 20 mA to 50 A
|
10 mV/A : 25 A to 250 A
100 mV/A : 20 mA to 25 A
|
| Noise (RMS) | 50 mA | 20 mA | 20 mA |
| Weight (Probe) | 390 g | 380 g | 370 g |
| Size (Probe) | 62.28 mm (W) x 151.85 mm (H) x 26.4 mm (D) | ||
| Intended Output Load | 1 MΩ | ||
| Clamp Dia. | 20 mm | ||
| Power Supply | DC 12 V / 2 A | ||
| Operating Temperature and Humidity | 0 °C to 50 °C / 20 %RH to 75 %RH | ||
| Insulated Line Voltage | 600 V CAT II / 300 V CAT III | ||
Note :
*1. 750 A peak at pulse width of ≤ 30 µs
*2. 500 A peak at pulse width of ≤ 30 µs
*3. 250 A peak at pulse width of ≤ 30 µs
Specifications subject to change without notice. GCP-0275/0550/2525_1D1DH
ORDERING INFORMATION
GCP-0275 2 MHz AC/DC Current Probe
GCP-0550 5 MHz AC/DC Current Probe
GCP-2525 25 MHz AC/DC Current Probe
ACCESSORIES
- Current Probe x 1
- Power Adapter with interchangeable Plugs x 1
- AC Plug Changeable (CN/US/UK/EU) x 1
- BNC to BNC Cable (with 50 ohm terminal) x 1
- Packing List x 1
Do you have a Current Probe that needs to be calibrated?
We offer standard traceable calibration and ISO 17025 accredited calibration services.
Get your Current Probe calibrated today! Click Here!