Soken DAC-VCTT-8 - Instrument Transformer Test Set

Instrument Transformer Test Set

Soken

Rated 0 / 5 (0 reviews)

Category : Instrument Transformer Testing Set

by quote only add to cart

Documents:

Overview
Features
Specifications
Calibration

DAC-VCTT-8 is an automatic balance bridge incorporating a current comparator-type transformer. The meter is desirable for measuring ratio errors and phase angles of instrument transformers according to the international standards IEC 60044-1 and -2. Combining an optional different-ratio adapter, DAC-RAC-2/RAV-2, different-ratio testing is also available.

 

Options: Ratio Adaptor DAC-RAV-2/RAC-2

Range of ratios to be set

Ks: Transformation ratio of a measurement standard
Kx: Transformation ratio of an instrument transformer to be tested
VT: DAC-RAV-2: Ks/Kx: 0.5000 - 2.0000
CT: DAC-RAC-2: Ks/Kx: 0.5000 - 2.0000

 

Optional Burdens

  • Current transformer (CT) testing in accordance with the current ratio error test of the international standard IEC 60044-1 is available.
  • Voltage transformer (VT) testing in accordance with the voltage error test of the international standard IEC 60044-2 is available.
  • The ratio error, phase displacement, test voltage, test current, and test frequency of CT/VT can be measured.
  • Units of indication, either “%” or “RCF” (Ratio Correction Factor) for the ratio error, and either “Min “(minutes) or “Crad” (centiradians) for the phase angle, are available. Thus, it is appropriate for ANSI/IEEE tests.
  • USB interface is a standard fixture.
  • Error values of standard VT/CT can be registered, and automatically compensated.
  • Registration: 10 units for each VT and CT (Test point: 20 points for every unit)
  • Different-ratio testing is available by incorporating an optional CT or VT different-ratio adapter.
  • An internal burden compensation circuit realizes the internal burden of DAC-VCTT-8 as small as 0.1VA.

 

General

Test MethodMake a comparison between the instrument transformer under test and the standard Transformer which having the same transformation ratio. (A standard voltage transformer or Current transformer is to be prepared by a user.)
Rated secondary and test range
CT
Rated Secondary: 1A, 5ATest Range: 1 ~ 200%
VT
Rated Secondary : 110, 120, 150, 200, 230, 63.5, 190/3VTest Range : 2 ~ 120%
Rated Secondary : 100/3, 110/3, 200/3VTest Range: 5 ~ 200%
Measurement Range
Ratio error (RCF) and Phase Angle
2% Range
Ratio Error± 1.999% (0.98040-1.02040)
Phase Angle± 99.9 min
20% Range
Ratio Error± 19.99% (0.83440-1.24984)
Phase angle± 999 min
Rated secondary Current: 0 – 210% of rated secondary current
Rated 1APhase Angle 0.000 – 2.100A
Rated 5APhase Angle 0.00 – 10.50A
Resolutions
Measurement Range 2%
Ratio Error: 0.001%Phase Angle: 0.1 min
Measurement Range 20%
Ratio Error: 0.01%Phase Angle: 1 min
1A Rated Secondary Current
Reading in % of rating: 0.1%Reading in current: 0.001A
5A Rated Secondary Current
Reading in % of rating: 0.1%Reading in current: 0.01A
Accuracy
Ratio error±(3%rdg + 2 digits) *±(3%rdg + 3 digits) when less than rated 20%
Phase angle±(3%rdg + 2 digits) *±(3%rdg + 3 digits) when less than rated 20%
Voltage/Current±(3%rdg + 3 digits)
Frequency±0.1Hz
Internal Burden0.1VA or less
InterfaceUSB (2.0/1.1) or GP-IB(as option)
Input powerAC100-240V ±10%, 50/60Hz
SizeW430 x H200 x D380 (mm)
WeightApprox. 20kg

Note: Specifications are subject to change without notice due to our commitment to continual product improvement.


Do you have a Instrument Transformer Test Set that needs to be calibrated?

We offer standard traceable calibration and ISO 17025 accredited calibration services.

Get your Instrument Transformer Test Set calibrated today! Click Here!

 